P30
Frequently asked questions (FAQ)
FAQ V1.01
12
© KEBA
2.3
Energy display (c and x series)
When is the charged power shown on the display?
Following a charging session, the energy of the completed charging session
is displayed. When starting up the device, the total energy output of the
charging station is displayed.
Can the power display be deactivated or permanently displayed?
No.
Does the charging station have a calibrated meter (MID certification)?
Certain variants of the c- and x-series have a calibrated meter. Whether the
charging station has a calibrated meter can be determined by the product
name. The “User’s Manual” describes how to determine this information from
the product designation. The product designation is shown on the type plate.
2.4
DC fault detection (DC fault current monitoring)
Can I disable the DC fault detection?
No. DC fault detection is a safety-related feature and can not be disabled.
Can the triggering current of DC fault detection be set?
No, the value is fixed in the P30 with a maximum of 6 mA tripping current.
Does the charging station restart after a detected DC fault and how often?
If a DC fault has been detected, the P30 attempts to restart up to 5 times
(auto-recovery).
What happens after the restart (auto-recovery)?
If the restart (auto-recovery) was unsuccessful, the vehicle must be discon-
nected.
How can the DC fault detection be checked during the initial commissioning?
The charging station has an initial start-up mode. In this mode, a check with
a corresponding vehicle simulator or a suitable test device is possible.