P30
Diagnostic options
FAQ V1.01
35
© KEBA
Disconnect the plug and wait until the charging station has cooled down.
If the error occurs repeatedly: Check that the device is mounted in a suitable
place.
AUTARK_LOCK_FAILED
Error group:
0x[xxx]4
The plug could not be locked.
Measures
Unplug the plug and quickly plug it in again.
If the problem persists, check the following:
●
Dirt in the socket
●
Use of a standard-compliant plug
●
Mechanical damage of the plug
●
Defect of the cable
AUTARK_OHMIC_LOAD
Error group:
0x[xxx]5
The charging station has not detected an electric vehicle but rather a unau-
thorized consumer. Only standard-compliant electrically operated vehicles
may be charged.
Measures
Remove the unauthorized consumer and restart the charging process.
AUTARK_IBN_MODE
Error group:
0x[xxx]7
The charging station is in commissioning mode.
Measures
Check the DIP switch settings for correct configuration and restart the charg-
ing process (see the "Installation Manual").
AUTARK_SHORT_CIRCUIT
Error group:
0x[xxx]8
The charging station has detected a short circuit.