P30
Diagnostic options
FAQ V1.01
34
© KEBA
ERROR_SYSTEM
Error group:
0x[xxx]f
The communication with the charging controller of the charging station is not
possible or there is an error in the firmware.
Measures
Disconnect the vehicle from the charging station and restart the charging
process.
If a software update is running: Software update has failed. Download the
software update again.
If the error persists: Contact the KEBA support.
4.2
Red/White error displays
This chapter covers the error messages shown in red/white on the LED bar.
AUTARK_PLUG_LOST
Error group:
0x[xxx]1
The plug was pulled out of the socket during charging or the plug was not
properly locked and released from the socket during charging.
Measures
Disconnect plug and reconnect, paying attention to the correct locking.
AUTARK_PLUG_UNDEF
Error group:
0x[xxx]2
The plug was not recognized.
Measures
Check if the plug is compliant with the standard.
AUTARK_OVERHEAT
Error group:
0x[xxx]3
Overtemperature shutdown: The permissible temperature in the charging
station has been exceeded.
Measures