If the error occurs repeatedly on the same vehicle: Have the vehicle checked
in the workshop. It may be necessary to replace the charge controller in the
vehicle.
ERROR_METER / ERROR_LED
Error group:
0x[xxx]6
Possible causes for this error are:
●
Communication error with the energy meter
●
Communication error with the LED controller
●
Configuration error of the energy meter
Error code
Cause
0x8006
Communication with the energy meter is faulty or not possible.
0x8046
A configuration error of the energy meter has occurred. The calibration
data may possibly be incorrect.
0x8056
Communication with the LED controller is faulty or not possible. This error
can occur immediately after a software update and is not critical in this
case.
0x8086
The energy meter does not provide any measured values.
0xa006
The coupling between charge controller and LED controller is faulty. This
error only occurs on devices with MID certification.
Measures
Verify that the DIP switches are configured correctly (see the "Installation
Manual").
If the error persists: Replace the charging station
ERROR_CFB
Error group:
0x[xxx]7
The internal switching-current or fault-current mechanism has triggered. The
feedback of the contactors on a control was not OK. Possible causes include
an error in the contactor monitoring function or a fused contactor. A fused
contactor is a non-resettable hard fault.
Measures
Cancel charging and switch off charging station for a short time (30 seconds)
via the line circuit breaker. Then restart the charging process.
If the error persists: The charging station is defective and must be sent in for
repair.