11. Reconnect cables.
12. Check the oil level in the oil separator tank.
Top up if necessary.
Maintenance of the control valve dirt trap must be carried out whenever the oil separator car‐
tridge is changed.
Further information Information on control valve dirt trap maintenance is given in chapter 10.4.5.
Making operational:
1. Reconnect the negative cable to the batteries.
2. Close the access door.
Dispose of old parts and contaminated materials according to environmental regulations.
Starting the machine and performing a test run:
1. Start the machine and run in IDLE until the operating temperature is reached.
2. Close the outlet valves.
3. Shut down the machine.
4. Wait until the machine has automatically vented.
Pressure gauge reads 0 bar!
5. Open the outlet valves.
6. Open the right-hand access door.
7. Check the oil level after about 5 minutes.
Top up if necessary.
8. Visually inspect for leaks.
9. Close the access door.
10 Maintenance
10.4 Compressor Maintenance
120
Service manual Portable compressor
M122
No.: 9_6974 20 E
RAMIRENT