Work on the diesel particulate filter
NOTICE
Damage of the diesel particulate filter!
➤ The machine must be shut down immediately if any damage or functional defect in the
diesel particulate filter is noticed.
➤ Only authorised specialists, such as KAESER Service Technicians may carry out main‐
tenance work on the diesel particulate filter.
10.2 Following the maintenance plans
10.2.1 Logging maintenance work
The maintenance intervals given are those recommended for KAESER original components
with average operating conditions.
➤ In adverse conditions, perform maintenance work at shorter intervals.
Adverse conditions are, e.g.:
■ high temperatures
■ much dust
■ frequent use
➤ Adjust the maintenance intervals with regard to local installation and operating condi‐
tions.
➤ Logging all maintenance work.
This enables the frequency of individual maintenance tasks and deviations from our recom‐
mendations to be determined.
Further information A list is given in chapter 10.9.
10.2.2 Maintenance tasks after commissioning
The table below lists maintenance tasks required after commissioning (initial start-up).
➤ Carry out maintenance tasks according to the following schedule.
Component:
Task
After the first 50 h
See chapter
Note
Engine
Check belt tension and re-ten‐
sion if necessary.
X
Engine
SM
Check coolant level.
X
Engine
SM
Wheels/chassis: