5. Lightly oil the new filter's gasket.
6. Turn the oil filter clockwise by hand to tighten.
7. Check the oil level in the oil separator tank.
Top up if necessary.
8. Reconnect the negative terminals to the batteries.
9. Close the access door.
Dispose of old cooling oil and any materials or parts contaminated with oil according to envi‐
ronment protection regulations.
Starting the machine and performing a test run:
1. Start the machine and run in IDLE until the operating temperature is reached.
2. Close the outlet valves.
3. Shut down the machine.
4. Wait until the machine has automatically vented.
Pressure gauge reads 0 bar!
5. Open the outlet valves.
6. Open the left-hand door.
7. Check the oil level after about 5 minutes.
Oil level too low: top up if necessary.
8. Visually inspect for leaks.
9. Close the access door.
10.4.5 Oil separator tank dirt trap maintenance
Material Cleaning cloth
Wrench
Small screwdriver
Maintenance kit, control valve
Petroleum ether or spirit
Precondition The machine is shut down.
The machine is fully vented, the pressure gauge reads 0 bar.
Machine is cooled down.
All compressed air consumers are disconnected and the air outlet valves are open.
Negative cable to the batteries disconnected.
10 Maintenance
10.4 Compressor Maintenance
116
Service manual Portable compressor
M122
No.: 9_6974 20 E