3. Keep the inlet and exhaust apertures free of obstructions so that the cooling air can flow freely
through the room.
4. Ensure clean air in order to support the proper functioning of the machine.
Further information See chapter 2.6 for ventilation aperture dimensions.
5.2.3 Prevention of thermal problems
Observe the following instructions to prevent thermal problems:
■ Make sure ventilation apertures are adequate.
■ Ensure correct location of the apertures (constant airflow).
■ Ensure correct machine positioning (all machines must be able to draw in cool fresh air).
■ Ensure that hot exhaust air leaves the room by the shortest direct path.
■ Do not exceed the permissible duty cycle.
➤ KAESER can offer advice in this respect.
5.2.4 Operating the machine in a compressed air network
When the machine is connected to a compressed air network, the network working pressure may
not exceed the permissible final pressure of the machine.
➤ Consult KAESER for advice on this subject.
5
Installation and Operating Conditions
5.2
Installation conditions
34
Assembly and operating manual 1-stage piston compressor
EPC-G
No.: 9_5752 24 E