10.13.2 Replacing the solenoid valve
Fig. 38 Replacing the solenoid valve
1
Solenoid valve
2
Screw connection
3
Damper
4
Connecting socket
1. Remove the connecting socket from the solenoid valve.
2. Unscrew the defective solenoid valve wit damper from double nipple.
3. Remove the damper from the solenoid valve.
4. Mount the new solenoid valve using sealing tape.
When fitting the solenoid valve make sure the direction of flow is correct as indicated by the
arrow on the body.
5. Screw the damper into the new solenoid valve using PTFE sealing tape.
6. Open the user's shut-off valve between the machine and the air distribution network.
7. Start the machine and visually check for leaks.
10.14 Cylinder head and valves
Material Compressed air for blowing out
Cleaning cloths
Brush
Spares (as required)
10.14.1 Checking cylinder head and valves
To check the valves' function, check the time required to charge the air receiver.
Precondition Machine at operating temperature.
1. Close the user's shut-off valve between the machine and the air distribution network.
2. Switch on the machine and measure the time required to charge an air receiver.
Result If you find considerable differences in the filling time compared to the machine's status after deliv‐
ery, check the valves for coking.
Further information See chapter 7.7 for more information about measuring the charging time for air receivers.
10 Maintenance
10.14 Cylinder head and valves
No.: 9_5752 24 E
Assembly and operating manual 1-stage piston compressor
EPC-G
77