Fig. 45 Setting the output pressure
4
Select menu option "set pressure in the oil
separator tank"
5
Minimum working pressure (lower setting
limit)
6
Setting scale with indicator bar
7
Maximum working pressure (upper setting
limit)
8
Current setting
➤ Use «RIGHT» and/or «LEFT» to select the output pressure and check on the instrument
panel pressure gauge.
The set pressure is saved when leaving the setting menu option.
➤ Press «esc» .
The display changes to show the operating mode.
8.2.5 Shutting down the machine
CAUTION
Thermal overload of the turbo charger.
Abrupt stopping of the engine under load can cause a fault or damage to the turbo charger.
➤ Run the engine a few minutes in idle before shutting down to allow the turbo charger to cool.
Operating the machine in the cool-down phase
➤ Press and hold the «Stop» key for longer than one second.
■ The machine switches to unloaded run-on, i.e. the engine runs at IDLE speed and the oil
separator tank is vented.
■ When the cool-down period has elapsed (engine setting "unloaded run-on") the machine has
cooled enough so that the engine can stop automatically.
■ The controller display shows
back pressure if the pressure in the oil separator tank is still
> 1 bar.
■ When the machine is fully vented, the display changes to
ready to start.
■ When the OST is fully vented after shutdown, the re-start inhibitor is activated and is indi‐
cated by the timer counting down from 20 seconds.
Shutting down the machine
If the machine is not to be used again, the «battery isolating switch» should be switched off.
8
Operation
8.2
Starting and stopping
No.: 9_9425 01 E
Service Manual Screw Compressor
M170 SIGMA CONTROL MOBIL
81