Fig. 33 Unit of pressure setting
E2
Unit of pressure setting menu
D1
Display unit bar (selected)
D2
Display unit psi
3
Navigation
A
Display field size (white background)
B
Selection choice (grey background)
1. Use the «UP» and/or «DOWN» arrow keys to select the required unit.
2. Press «Enter» .
The setting is saved.
3. Press «esc» .
Result The display changes to show the operating mode.
7.5 Entering a password
No password is set when the machine is delivered.
■
— Password level 0
The following password is required to make entries and changes in the settings menu:
■
— Password level 1 (renter password): 4512
The following displays will require you to enter the password:
Fig. 34 Waiting for password entry
The cursor flashes at the position for the first letter of the password.
1. Keep on pressing the «DOWN» or «UP» key until the required character appears.
2. Use «RIGHT» to move the cursor to the position of the second letter.
The cursor flashes in the position for the next letter of the password.
3. Set the remaining characters of the password until it is complete.
4. Confirm the password with «Enter» .
The activated password is displayed. (see example in figure 35).
7
Initial Start-up
7.5
Entering a password
No.: 9_9425 01 E
Service Manual Screw Compressor
M170 SIGMA CONTROL MOBIL