No.1 to No.5
Action
Selects the action to perform when the alarm is
activated.
0
Disable:
Performs no action.
0
Mail:
Sends out e-mail. Specify the recipient’s mail
address. The subject of the mail is “Alarm from
{model name}”.
(For example, the subject is Alarm from
VN-H657WPB in the case of VN-H657WPBU.)
Enter the message to send in [Mail Text]. Enter
a message not longer than 127 characters.
To attach an image to the mail, set [JPEG
Attachment] to “ON”.
0
TCP:
Sends the text string input in the [TCP Data] field
via TCP to the recipients specified in [TCP IP
Address] and [TCP Port Number].
0
UDP:
Sends the text string input in the [UDP Data] field
via UDP to the recipients specified in [UDP IP
Address] and [UDP Port Number].
0
Switch Scene File:
Specifies the filming scene.
0
Position:
Moves to the position set at [Action Position
Number].
p.58 [ Action Position Number ] )
0
Play Audio:
Plays back an audio file registered to the
camera.
For details about the audio file settings, refer to
[Audio File
No.1 to No.5] on the [Audio] page.
0
Pin Output1 Make:
Changes Pin Output1 to Make.
0
Pin Output1 Break:
Changes Pin Output1 to Break.
0
Pin Output2 Make:
Changes Pin Output2 to Make.
0
Pin Output2 Break:
Changes Pin Output2 to Break.
[Set values:
R
Disable, Mail, TCP, UDP, Switch
Scene File, Position, Play Audio, Pin Output1
Make, Pin Output1 Break, Pin Output2 Make, Pin
Output2 Break]
1st Trigger
Select the 1st trigger to perform an action.
[Set values:
R
Pin Input1 Make, Pin Input1 Break,
Pin Input2 Make, Pin Input2 Break, Position, Audio
Detection1, Audio Detection2, Motion Detection,
Tampering Detection, Time, Day/Night, FAN Stop]
Memo :
0
If you set the [2nd Trigger] to “Disable”, an action
will be performed when only [1st Trigger] is
triggered.
0
[Max. Interval] and [2nd Trigger] can be selected
only when input terminal (“Pin Input1 Make”, “Pin
Input1 Break”, “Pin Input2 Make”, or “Pin Input2
Break”) is selected for the [1st Trigger] trigger.
Max. Interval
This is available when both [1st Trigger] and [2nd
Trigger] are set.
Specify the maximum interval between each
trigger for [1st Trigger] and [2nd Trigger].
An action will be performed if [2nd Trigger] occurs
within the maximum time interval after [1st
Trigger] occurs.
[Set values: 1
sec to 3600
sec]
2nd Trigger
Select the 2nd trigger to perform an action.
[Set values:
R
Disable, Pin Input1 Make, Pin Input1
Break, Pin Input2 Make, Pin Input2 Break]
0
Mail Settings:
If you have set the [SMTP Server], [Port
Number], and [Send Mail Address] on the [Alarm
Environment] page, the “Preset” message is
shown. If not set, the “Unset” message is shown.
p.59 [[Alarm Environment] Page] )
0
Mail Address:
Enter the recipient’s mail address.
0
Mail Text:
Enter the mail text. Input not more than 127
characters.
[Advanced Settings] Page -[Alarm] Page
57
Se
tti
ng
Us
in
g In
ter
net
E
xplor
er