4
Mount the fall prevention wire (for
ceiling; to connect the ceiling mount
section to the ceiling).
.
Φ4 to 5.5 mm
Φ9 mm and below
6 mm
6 mm and below
Fall-prevention Wire
(for ceiling)
Fall-prevention
Wire (for ceiling)
Note :
0
Take note of the length, strength, pull and
material (insulation) of the fall prevention wire
(for ceiling) and use one with a wire strength of
more than 20 k
g
.
0
The inner diameter of the ring section of the fall
prevention wire mounted on the camera should
be Φ4 mm and above and Φ5.5 mm and below,
and the outer diameter should be Φ9 mm and
below.
0
The thickness of the screw head and the wire
(including the washer) should be 6 mm and
below. If it is more than 6 mm, the screw will
touch the ceiling and the camera cannot be
installed horizontally.
0
Use M4 fixing screws.
Memo :
0
The wire should be insulated from the ceiling
structure. If the ceiling structure is metal and
insulation is not provided between the camera
and the ceiling structure, image noise may
occur.
5
Connect the power cable.
0
To supply power from an AC 24 V power
supply, connect a power cable.
0
To supply power via PoE plus, you do not
need to connect a power cable. Go to the
next step.
p.26 [Connect the LAN cable.] )
.
To AC 24 V
terminal
Power cable
Power cord for connecting to AC 24
V
(Reference value)
Conductor Diameter
(mm)
Maximum connection
distance (m)
Φ1.0 and above
40
Φ1.6 and above
130
Φ2.0 and above
200
Φ2.6 and above
350
Memo :
0
The default IP address setting is 192.168.0.2.
Note :
0
For safety reasons, turn on the power only after
ensuring that all the connections are in place.
0
If power is supplied from both power cable and
LAN cable, priority will be given to the power
supply from the power cable.
0
If multiple cameras are turned on
simultaneously in the same LAN environment,
access attempts may fail due to IP address
duplication. Set up an IP address by either using
the JVC-VN-IP SettingTool (included on the
supplied CD-ROM) or turning the power supply
of each camera on separately to avoid
duplication.
Installation and Connection Preparations (VN-H657BU)
25
Moun
tin
g
the
Ca
m
era