SECTION 3
Adjustment method
3.1 MD adjustment(Auto adjust)
Press MD REC button and
POWER button together,
then connect AC cord.
INDICATION
"TEST MODE1"
Power to ON by MD PLAY
button by main body,then MD
to stop by STOP button on
meinbody.
Complete setting
set to MD
adjustment mode
Press PLAY MODE
button of remote controller
INDICATION
"TEST MODE1"
INDICATION
"TEST MODE1"
Comolete the Initialize
of EEPROM
INDICATION
"TEST MODE1"
Set to MD
adjustment mode
Insert the sensor of
laser power meter
Setting the PLAYBACK
LASER POWER
Press 2 button of
remote controller
Press STOP button of
remote controller
Adjust to
morthsn 0.68mW or
same as 0.68mW
Complete the PLAYBACK
LASER POWER adjustment
Laser power to
up by F.SKIP button
of remote controller
Laser power to
down by B.SKIP button
of remote controller
Setting the RECORDING
LASER POWER
Press 4 button of
remote controller
Press STOP button of
remote controller
Adjust to
less than 6.23mW or
same as 6.23mW
Eject the sensor to laser
power meter by EJECT
button of main body
Laser power to up
by F.SKIP button of
remote controller
Laser power to down
by B.SKIP button of
remote controller
Complete the RECORDING
LASER POWER adjustment
(1) Setting of MD adjustment
(2) Initialize of EEPROM
(3) Adjust the laser power