Chapter 7---Troubleshooting
Model 250 Service Manual
7-15
Deflection Path
Figure 7-12
CRT Deflection path from Raster Timing Generator PCB.
The Raster Timing Generator PCB receives the horizontal and vertical sync
pulses from the Video Processor PCB, and uses a Phase Locked Loop circuit to
lock to the horizontal sync. It sends a sample of the horizontal frequency
(H_DRIVE) to the Horizontal Vertical Deflection PCB to set the timing of the
Horizontal Amplifier, a Switched Mode Power Supply that generates the
horizontal deflection sawtooth waveform. The Raster Timing Generator PCB
divides the range of horizontal scan frequencies into four groups or bands because
the retrace or flyback timing varies dramatically from the lowest frequency (15
kHz) to the highest frequency (90 kHz).
The Horizontal Vertical Deflection PCB generates the horizontal waveforms that
drive the CRT Yokes. Many of the geometric corrections are integrated into the
horizontal waveform at the Horizontal Vertical Deflection PCB such as
Pincushion, Keystone, Skew, and Bow. The vertical size is be adjusted on the
Horizontal Vertical Deflection PCB.
Summary of Contents for 250
Page 16: ...Chapter 2 System Description Model 250 Service Manual 2 9 ...
Page 43: ...Chapter 4 Optical 4 10 Model 250 Service Manual Figure 4 6 Optical Path ...
Page 55: ...Chapter 5 Optical 3 4 22 Model 100 Service Manual ...
Page 91: ...Chapter 5 Electronics 5 36 Model 250 Service Manual Figure 5 22 Scan Reversal PCB I O Diagram ...
Page 131: ...Chapter 5 Electronics 5 76 Model 250 Service Manual Figure 5 44 Backplane Diagram right side ...
Page 132: ...Chapter 5 Electronics Model 250 Service Manual 5 77 ...
Page 138: ...Chapter 6 Miscellaneous Items 6 6 Model 250 Service Manual ...
Page 167: ...Chapter 7 Troubleshooting Model 250 Service Manual 7 29 ...
Page 181: ...Chapter 8 Software and Protocol 8 14 Model 250 Service Manual ...
Page 185: ...Chapter 9 Parts List 9 4 Model 250 Service Manual ...