14. Power on the services gateway. The OK LED on the power supply faceplate should blink, then light
steadily.
15. Verify that the SPC is functioning correctly by issuing the show chassis fpc and show chassis fpc
pic-status commands.
Figure 133: Installing an SPC
g030216