12. After verifying, commit the configuration.
root@#commit
Network traffic fails over to the secondary node.
13. Verify that the failover was successful by checking the session tables and network traffic on the
secondary node.
admin@cluster#show security flow session summary
admin@cluster#monitor interface traffic
14. Upgrade the Junos OS release on the primary node from 12.3X48-D10 to 15.1X49-D10.
admin@cluster#request system software add <location of package/junos filename> no-validate no-copy
Ignore error messages pertaining to the disconnected cluster.
15. Power on the primary node.
admin@cluster#request system reboot
See:
•
Powering On an AC-Powered SRX5400 Services Gateway
•
Powering On a DC-Powered SRX5400 Services Gateway
•
Powering On an AC-Powered SRX5600 Services Gateway on page 223
•
Powering On a DC-Powered SRX5600 Services Gateway on page 227
•
Powering On an AC-Powered SRX5800 Services Gateway
•
Powering On a DC-Powered SRX5800 Services Gateway
16. Perform the hardware upgrade on the primary node by replacing SCB2 with SCB3, IOC2 with IOC3,
and the existing midplane with the enhanced midplane.
Perform the following steps while upgrading the SCB.
To upgrade the Routing Engine on the primary node:
a. Before powering off the secondary node, copy the configuration information to a USB device.
b. Replace RE1 with RE2 and upgrade the Junos OS on RE2.
287
Summary of Contents for SRX5600
Page 1: ...SRX5600 Services Gateway Hardware Guide Published 2020 02 14 ...
Page 23: ......
Page 105: ...LEDs 106 ...
Page 114: ...Figure 51 SRX5K MPC g030309 MPC empty 115 ...
Page 124: ...Port and Interface Numbering 125 ...
Page 130: ...Port and Interface Numbering 131 ...
Page 156: ......
Page 185: ......
Page 193: ...Figure 84 Installing the Front Mounting Hardware for a Four Post Rack or Cabinet 196 ...
Page 239: ......
Page 285: ...c Upload the configuration to RE2 from the USB device 288 ...
Page 372: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the SRX5600 377 ...
Page 373: ......
Page 407: ......
Page 420: ...423 ...
Page 423: ...Restricted Access Area Warning 426 ...
Page 430: ...433 ...
Page 443: ...Jewelry Removal Warning 446 ...
Page 446: ...Operating Temperature Warning 449 ...
Page 456: ...DC Power Disconnection Warning 459 ...
Page 460: ...DC Power Wiring Sequence Warning 463 ...
Page 463: ...DC Power Wiring Terminations Warning 466 ...
Page 466: ...DC Power Disconnection Warning 469 ...
Page 470: ...DC Power Wiring Sequence Warning 473 ...