Powering On a DC-Powered SRX5600 Services Gateway
To power on a DC-powered services gateway:
1. Verify that an external management device is connected to one of the Routing Engine ports (AUX,
CONSOLE, or ETHERNET).
2. Turn on the power to the external management device.
3. Verify that the power supplies are fully inserted in the chassis.
4. Verify that the source power cables are connected to the appropriate terminal: the positive (+) source
cable to the return terminal (labeled RETURN) and the negative (–) source cable to the input terminal
(labeled –48V).
5. Switch on the dedicated customer site circuit breakers to provide power to the DC power cables. Follow
your site’s procedures.
6. Check the INPUT OK LED is lit steadily green to verify that power is present.
7. If power is not present:
•
Verify that the fuse is installed correctly and turn on the breaker at the battery distribution fuse board
or fuse bay.
•
Check the voltage with a meter at the terminals of the power supply for correct voltage level and
polarity.
8. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to
one of the ESD points on the chassis.
9. Move the DC circuit breaker on each of the power supplies to the on (—)position.
10. Verify that the BREAKER ON LED is lit green steadily.
11. Verify that the PWR OK LED is lit green steadily, indicating the power supply is correctly installed and
functioning normally.
If the power supply is not functioning normally, repeat the installation and cabling procedures.
227
Summary of Contents for SRX5600
Page 1: ...SRX5600 Services Gateway Hardware Guide Published 2020 02 14 ...
Page 23: ......
Page 105: ...LEDs 106 ...
Page 114: ...Figure 51 SRX5K MPC g030309 MPC empty 115 ...
Page 124: ...Port and Interface Numbering 125 ...
Page 130: ...Port and Interface Numbering 131 ...
Page 156: ......
Page 185: ......
Page 193: ...Figure 84 Installing the Front Mounting Hardware for a Four Post Rack or Cabinet 196 ...
Page 239: ......
Page 285: ...c Upload the configuration to RE2 from the USB device 288 ...
Page 372: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the SRX5600 377 ...
Page 373: ......
Page 407: ......
Page 420: ...423 ...
Page 423: ...Restricted Access Area Warning 426 ...
Page 430: ...433 ...
Page 443: ...Jewelry Removal Warning 446 ...
Page 446: ...Operating Temperature Warning 449 ...
Page 456: ...DC Power Disconnection Warning 459 ...
Page 460: ...DC Power Wiring Sequence Warning 463 ...
Page 463: ...DC Power Wiring Terminations Warning 466 ...
Page 466: ...DC Power Disconnection Warning 469 ...
Page 470: ...DC Power Wiring Sequence Warning 473 ...