NOTE:
After a PSM and a PDM are powered on, it can take up to 60 seconds for status
indicators—such as the output status LEDs on the PSM, and the command output on the
craft interface—to indicate that the PSM and PDM are functioning normally. Ignore error
indicators that appear during the first 60 seconds.
10. Verify that the PWR OK LED on the AC PSM faceplate is lit steadily, indicating that PDM is correctly
installed, functioning properly, and providing power to the AC outputs.
11. On the external management device connected to the Routing Engine, monitor the startup process to
verify that the system has booted properly.
12. Verify that the router powers up and goes through the system initialization process.
RELATED DOCUMENTATION
Initially Configuring the MX2010 Router | 351
Maintaining and Verifying the Status of the MX2010 Router Components | 609
Initially Configuring the MX2020 Router
Maintaining and Verifying the Status of the MX2020 Router Components
MX2000 Three-Phase Delta AC Power Distribution Module Description | 100
MX2000 Three-Phase Wye AC Power Distribution Module Description | 102
Connecting the MX2000 Series Router to a Console or Auxiliary Device | 338
Connecting AC Power to an MX2000 Router with Three-Phase Delta AC Power Distribution
Mapping Input Power from AC Power Distribution Modules to AC Power Supply Modules on MX2000
Preventing Electrostatic Discharge Damage to an MX2010 Router
Preventing Electrostatic Discharge Damage to an MX2020 Router
Troubleshooting the MX2000 Router Power System
Problem
Description: The following alarms, LEDs, and other conditions indicate a problem with the AC or DC power
system:
320
Summary of Contents for MX2010
Page 1: ...MX2010 Universal Routing Platform Hardware Guide Published 2019 12 03...
Page 28: ......
Page 30: ...MX2010 Power System Description 95 MX2010 Cooling System Description 45 4...
Page 144: ...MX2010 DC Power 48 V System Electrical Specifications 201 122...
Page 146: ......
Page 233: ......
Page 273: ...Figure 98 Loading the MX2010 Router into the Rack g007436 256...
Page 294: ...Figure 113 Reinstalling an AC Power Distribution Module g007440 D 277...
Page 295: ...Figure 114 Reinstalling a DC Power Distribution Module 48 V D g007432 278...
Page 373: ...4 PART Installing and Replacing Components Installing Components 359 Replacing Components 429...
Page 374: ......
Page 620: ......
Page 715: ...6 PART Troubleshooting Hardware Troubleshooting Components 703...
Page 716: ......
Page 744: ......
Page 772: ......
Page 775: ...763...
Page 783: ...772...
Page 796: ...Jewelry Removal Warning 787...
Page 799: ...Operating Temperature Warning 790...
Page 808: ...DC Power Disconnection Warning 799...
Page 812: ...DC Power Wiring Sequence Warning 803...