If all AC or DC power supply modules (PSMs) have failed, the system temperature might have exceeded
the threshold, causing the system to shut down. See Step
for instructions on how to restart a
high-capacity AC or DC PSM after a shut down due to an over-temperature situation.
•
The yellow PWR OK LED blinks when an AC or a DC PSM is out of the power limit or is in an overcurrent
condition.
•
The red FAULT LED lights when the PSM is not receiving enough airflow to maintain the proper
temperature.
•
The red FAULT LED lights when the AC or DC output voltages are not within range.
•
The yellow INP0 LED blinks when the AC or DC voltage is present, but out of limits. This LED blinks
continuously for approximately a few seconds on and a few seconds off.
•
The yellow INP1 LED blinks when the AC or DC voltage is present, but out of limits. This LED blinks
continuously for approximately a few seconds on and a few seconds off.
•
The red -48V LED lights when the wrong polarity of DC input voltage is connected on the DC PDM.
Solution
To troubleshoot the MX2000 router power system:
1. Check the LEDs on all AC or DC PSM faceplates.
•
PWR OK PSM LED is blinking—Check the fans and air filters to be sure that they are functioning and
providing sufficient airflow through the chassis.
•
PWR OK PSM LED is off and no red alarm condition exists—Check that the circuit breakers are
switched to the ON position. Check that the AC or DC power switch is in the on (|) position.
•
PWR OK LED on PSMs is not lit—Check that the PSMs are inserted and are operating.
•
If an AC PSM or a DC PSM is correctly installed and functioning normally, the PWR OK, INP0, and
INP1 LEDs light steadily, and the FAULT LED is not lit.
2. Check the LEDs on each DC power distribution module (PDM) faceplate.
•
–48V or 240 V China PDM LED is off—Check that the PDM is receiving voltage.
•
–48V or 240 V China PDM LED is lit red—Check that the PDM is connected to correct input voltage
and polarity.
NOTE:
This does not apply to the 240 V China DC PDM.
•
Check that the DC PDM switch is set to 60 A or 80 A depending on the current feed coming from
the DC source circuit breaker.
321
Summary of Contents for MX2010
Page 1: ...MX2010 Universal Routing Platform Hardware Guide Published 2019 12 03...
Page 28: ......
Page 30: ...MX2010 Power System Description 95 MX2010 Cooling System Description 45 4...
Page 144: ...MX2010 DC Power 48 V System Electrical Specifications 201 122...
Page 146: ......
Page 233: ......
Page 273: ...Figure 98 Loading the MX2010 Router into the Rack g007436 256...
Page 294: ...Figure 113 Reinstalling an AC Power Distribution Module g007440 D 277...
Page 295: ...Figure 114 Reinstalling a DC Power Distribution Module 48 V D g007432 278...
Page 373: ...4 PART Installing and Replacing Components Installing Components 359 Replacing Components 429...
Page 374: ......
Page 620: ......
Page 715: ...6 PART Troubleshooting Hardware Troubleshooting Components 703...
Page 716: ......
Page 744: ......
Page 772: ......
Page 775: ...763...
Page 783: ...772...
Page 796: ...Jewelry Removal Warning 787...
Page 799: ...Operating Temperature Warning 790...
Page 808: ...DC Power Disconnection Warning 799...
Page 812: ...DC Power Wiring Sequence Warning 803...