Mirus for H2 Classic GrainGage
45
H2 Classic GrainGage Calibration
4 .2 Weigh Bucket Calibration
Weigh bucket calibration ensures the accuracy of the GrainGage’s weight calculations. This calibration
should be done on initial setup.
4.2.1 Calibrate Weigh Bucket
Use the weight calibration wizard and the larger weight (11 lb (5 kg)) included with the GrainGage to
calibrate the weigh bucket load cells.
1. Park the combine on a level surface.
2. Shut off the engine and keep the GrainGage powered
on.
3. Make sure the weigh bucket is empty.
4. Go to
Home
>
Setup
>
H2 GrainGage
.
5. Tap
Calibration
.
6. Tap
Bucket Weight Calibration
.
7. Select
Open Calibration Wizard
.
8. Follow the on-screen instructions.
Summary of Contents for HarvestMaster mirus H2
Page 1: ......
Page 7: ...CHAP TER ONE Mirus Ins tallation...
Page 11: ...Mirus and GrainGage S etup CHAP TER T WO...
Page 32: ...H2 Clas sic GrainGage Diagnos tic s and Aler t s CHAP TER THREE...
Page 42: ...GrainGage Calibration CHAP TER FOUR...
Page 71: ...Field Maps CHAP TER FIVE...
Page 98: ...Har ves t Mode CHAP TER SIX...
Page 120: ...Standard Grain Information APPENDIX A...
Page 123: ...Troubleshooting APPENDIX B...
Page 129: ...Limited Warrant y APPENDIX C...