Mirus for H2 Classic GrainGage
38
H2 Classic GrainGage Diagnostics and Alerts
Test Weight Diagnostics
Item
Description
Test Weight
Real time test weight (lb/bu or kg/hL) of grain in the chamber .
Chamber Weight
Real time weight (lb or kg) of the grain in the chamber . This value does
not include the weight of the chamber .
Load Cell 3 millivolts
The live operating voltage of the test weight load cell .
Test Weight Q
This multiplier corrects the test weight measurement based on the
slope and motion of the weighing platform .
Test Weight Tare Check
Test weight value (lb/bu or kg/hL) at the time the system last
performed a tare check .
3.1.6 Level Detect Diagnostics
On the Level Detect Diagnostics screen, Mirus displays
the status of the Overflow Sensor. It should be Untripped
when the weigh bucket is empty.
Note: Currently, only H2 Classics mounted on Wintersteiger
Quantum or Classic Plus combines are equipped with an
overflow sensor that trips when grain is in close proximity.