Mirus for H2 Classic GrainGage
127
Appendix B: Troubleshooting Mirus
8.3.3 Can’t Connect to GrainGage
If you are having trouble connecting to the GrainGage,
1. Ensure the H2 System Controller is turned on.
2. Ensure the H2 GrainGage plugin is enabled. For instructions on how to enable the plugin see
3. Check there is a solid green power light and flashing yellow status light on each of the modules.
4. Ensure all the cables are properly connected.
•
A USB or serial cable between the dock and the H2 System Controller.
•
A CAN cable between the H2 System Controller and the H2 GrainGage.
5. Turn off the H2 System Controller, Mirus, and the tablet, leave them off for 30 seconds, then turn them
back on and attempt to connect.
6. Unplug the CAN and power cables on the modules, leave them for 30 seconds, then plug them back
in and attempt to connect.
7. If the problem persists, contact the HarvestMaster Field Service Engineers.
8.3.4 Tare Warnings
A tare warning can be prompted for the reasons explained in the table below.
Tare Warnings
If
Then
Debris is in the bucket
or test chamber .
Check the bucket and test chamber to ensure that there is
nothing remaining (grain, debris, trash, etc .) .
Positive or negative
tension is on the weigh
bucket or load cells .
Move any air hoses, cables, or overload protection pins putting
tension on the weigh bucket or load cells .
Leftover grain is in the
weigh system .
The evacuation time is not long enough for the grain to fully
empty out of the GrainGage .
•
Go to
Setup
>
Sensors
>
Weight
>
Evacuation Time
.
•
Lengthen the evacuation time by 500 milliseconds .
•
Harvest another plot and check again .
Tare warning values
have been adjusted .
Restore the values to the default setting . See the
.
If the problem persists, contact the HarvestMaster Field Service Engineers.
Summary of Contents for HarvestMaster mirus H2
Page 1: ......
Page 7: ...CHAP TER ONE Mirus Ins tallation...
Page 11: ...Mirus and GrainGage S etup CHAP TER T WO...
Page 32: ...H2 Clas sic GrainGage Diagnos tic s and Aler t s CHAP TER THREE...
Page 42: ...GrainGage Calibration CHAP TER FOUR...
Page 71: ...Field Maps CHAP TER FIVE...
Page 98: ...Har ves t Mode CHAP TER SIX...
Page 120: ...Standard Grain Information APPENDIX A...
Page 123: ...Troubleshooting APPENDIX B...
Page 129: ...Limited Warrant y APPENDIX C...