background image

Maintenance 6

Maintenance

Only qualified mechanics with proper tools and 
knowledge should attempt to service this pump .

 Heavy parts . use lifting gear of appropriate 

capacity positioned directly over lift point(s).

Seal Lubrication

oil in the seal chamber should be changed after the first 
300 operating hours, then each 1000 hours thereafter or 
annually. the oil fill/oil drain opening is labled “oHl”. 
after cleaning and sanitizing the pump, drain all oil and 
residue into a clean measuring container.
•  If the oil is milky in appearance, it is contaminated 

with water. refill pump with clean, fresh oil, using 
amounts and type shown in Maintenance. check oil 
condition again after 300 operating hours.

•  If the oil is contaminated with both water and 

pollutants, the main seal must be replaced and 
the oil changed. recheck oil condition after 
300 operating hours.

NOTICE: Whenever the main seal is being serviced, 
remove oil and replace with new oil at reassembly. use 
only sae 5W-15W (Iso 22-44) mineral oil.
the filling quantity is shown in Product Specifications
NOTICE: Fill oil reservoir with the exact quantity of oil 
specified. the pump will become inoperable if overfilled.

Cutting Rotor

 Risk of electrical shock, cuts, and possible 

unexpected starts . disconnect the electrical power and 
keep your hands away from the pump inlet opening when 
working on or handling the pump for any reason. do not 
use automatic reset controls with this pump.
1.  disconnect the electrical power supply.
2.  disconnect the discharge piping (this step is not 

necessary if you have a guide-rail lift-out system).

3.  Hoist the pump out of the pit using the lift-out 

system or the lifting chain (not the cord) and place 
the pump in a suitable area where it can be cleaned. 

4.  remove all scale and deposits from the pump. check 

visual appearance of all pump housing screws and 
mating surfaces. tighten any loose fasteners.

 

 Risk of infection . pathogens (such 

as hepatitis) can collect on pump during normal 
operation. submerge the complete pump in a 
disinfectant solution (dilute chlorine bleach) for at 
least one hour before disassembly.

5.  using a feeler gauge, measure the cutting clearance 

between the cutting rotor and the cutting plate. see 
Figure 6.

6.  If cutting clearance is more than .007” (0.2 mm) 

wedge the cutting rotor with a piece of wood and 
unscrew socket head capscrew. 

7.  remove compression washer, cutting rotor, and one 

adjusting shim. replace cutting rotor, compression 
washer and socket head capscrew.

8.  Block cutting rotor with a piece of wood and tighten 

socket head capscrew to 5.9 ft-lb (8 nm).

9.  Verify cutting rotor moves freely and cutting 

clearance is less than .007” (0.2 mm). If clearance is 
still too large, repeat steps 6-9.

Cutting Plate

after cleaning and sanitizing the pump, inspect the cutting 
plate and verify absence of cracks, tears or gouges.
1.  If damaged, replace cutting plate by removing 

cutting rotor (as described above), then remove four 
socket head capscrews that attach plate to volute.

2.  replace cutting plate and four socket head 

capscrews. tighten capscrews to 5.9 ft-lb (8 nm).

3.  replace adjusting shims, compression washer, 

cutting rotor and socket head capscrews.

4.  Block cutting rotor with a piece of wwod and tighen 

socket head capscrew to 5.9 ft-lb (8 nm).

5.  Verify cutting rotor moves freely and cutting 

clearance is less than .007” (0.2 mm). If not correct, 
repeat steps 6-9 in previous procedure. 

Cleaning the Impeller

1.  to clean the impeller and volute, remove the cutting 

rotor, as described previously.

2.  unscrew four 5 mm allen screws attaching the 

volute and remove the volute casing. It may be 
necessary to tap around the parting line with a lead 
or rawhide hammer to loosen the casing.

 Risk of cuts . Worn impellers can have sharp 

edges that could cut or scratch. Wear protective gloves.
3.  carefully clean the impeller and volute surfaces. 

Inspect for obvious cracks or damage.

4.  reverse steps 1 to 3 to reassemble the pump.

6259 0910

Figure 6: Cutting clearance measurement location.

Summary of Contents for MULTICUT G2D-01

Page 1: ...ci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 800 642 5930 Espa ol Paginas 24 34 2012 JP913 01 24 12 Installation and Operator s Manual...

Page 2: ...ump s capacity electrical or mechanical failure in the pump etc may prevent your pump from functioning normally To prevent possible damage consult your dealer about installing a secondary sewage pump...

Page 3: ...r immediately Thank you for purchasing this Jung Pumpen product To help ensure years of trouble free operation please read the manual carefully This pump may be installed on an optional guide rail lif...

Page 4: ...e must be within 10 of the nameplate voltage If in doubt consult a licensed electrician 5 Connect the pump to its own dedicated circuit with no other load on the circuit Figures 3 4 5 show single and...

Page 5: ...nd possible unexpected starts Rotation of the cutter with hands in the cutter area can cause loss of fingers Disconnect the electrical power and keep your hands away from the pump inlet opening when w...

Page 6: ...sk of infection Pathogens such as hepatitis can collect on pump during normal operation Submerge the complete pump in a disinfectant solution dilute chlorine bleach for at least one hour before disass...

Page 7: ...e motor shaft If necessary use a flat blade screwdriver to help pry the seals from the shaft 9 Unscrew four capscrews and remove the bracket from the motor housing 10 Use a flat blade screwdriver and...

Page 8: ...uously Liquid level control cords tangled Untangle cords for free operation Pump is airlocked Stop pump for about one minute then restart Repeat stopping and starting until the airlock clears If the a...

Page 9: ...Repair Parts 9 Repair Parts 6332 1110 1 2 8 3 4 7 6 3 5 3...

Page 10: ...3907 G2DT 43 RP JP43638 G3D 01 RP JP43652 RP JP43610 RP JP21454 RP JP40381 RP JP43696 RP JP21876 RP JP43868 RP JP43869 RP JP43870 G3D 21 G3D 03 RP JP43641 RP JP20875 RP JP43063 RP JP43699 RP JP43700 G...

Page 11: ...erating a three phase motor with single phase power through a phase converter will void the warranty Note also that three phase motors must be protected by three leg ambient compensated extra quick tr...

Page 12: ...8 4 14 9 221 9 8 73 103 4 06 217 1 8 55 136 5 5 37 349 5 13 76 G2DT 23 G2DT 43 G2D 01 417 16 42 247 9 72 123 4 84 254 5 10 02 141 5 55 387 15 24 G2D 21 G2D 03 378 4 14 9 221 9 8 73 103 4 06 217 1 8 55...

Page 13: ...ous aupr s de votre d taillant concernant l installation d une deuxi me pompe d eaux d gout ou d une alarme de niveau lev de l eau Consultez la section D pannage de ce manuel pour obtenir des renseign...

Page 14: ...transporteur Nous vous remercions d avoir achet ce produit Jung Pumpen Pour vous assurer des ann es de fonctionnement sans probl me veuillez lire ce manuel attentivement Cette pompe peut tre mont e s...

Page 15: ...En cas de doute consultez un lectricien agr 5 Raccordez la pompe son propre circuit d di sans aucune autre charge sur celui ci Les figures 3 4 et 5 repr sentent des sch mas de c blage monophas et trip...

Page 16: ...e signal tique Utilisation Dilac rateur dangereux et ventuels d marrages inopin s Si vos mains se trouvent dans la zone de rotation du dilac rateur lorsque celui ci tourne vous risquez de perdre des d...

Page 17: ...aient se d poser sur la pompe lors de son fonctionnement normal Plongez compl tement la pompe dans une solution d sinfectante base d agent de blanchiment dilu pendant au moins une heure avant de la d...

Page 18: ...de l arbre 9 D vissez quatre vis d assemblage et retirez le support du carter du moteur 10 Utilisez un tournevis lame plate et d gagez tr s pr cautionneusement la moiti de joint inf rieure de la cavit...

Page 19: ...rement La pompe est bloqu e par de l air Arr tez la pompe pendant une minute environ puis red marrez la R p tez l arr t et le d marrage jusqu ce que le blocage par l air soit limin Si le blocage persi...

Page 20: ...Pi ces de rechange Pi ces de rechange 20 6332 1110 1 2 8 3 4 7 6 3 5 3...

Page 21: ...G3D 01 RP JP43652 RP JP43610 RP JP21454 RP JP40381 RP JP43696 RP JP21876 RP JP43868 RP JP43869 RP JP43870 G3D 21 G3D 03 RP JP43641 RP JP20875 RP JP43063 RP JP43699 RP JP43700 G3D 23 RP JP43909 G3D 43...

Page 22: ...galement que les moteurs triphas s doivent tre prot g s par des relais de surcharge thermocompens s tripolaires d clenchement ltrarapide du calibre recommand ou la garantie sera nulle Votre seul recou...

Page 23: ...T 03 378 4 14 9 221 9 8 73 103 4 06 217 1 8 55 136 5 5 37 349 5 13 76 G2DT 23 G2DT 43 G2D 01 417 16 42 247 9 72 123 4 84 254 5 10 02 141 5 55 387 15 24 G2D 21 G2D 03 378 4 14 9 221 9 8 73 103 4 06 217...

Page 24: ...ionario sobre la posibilidad de instalar una segunda bomba cloacal o una alarma de alto nivel de agua Consulte la secci n de Localizaci n de fallas en este manual para obtener informaci n sobre los pr...

Page 25: ...mediatamente una reclamaci n a la empresa de transporte Gracias por su compra de este producto Jung Pumpen Para garantizar a os de operaci n sin problemas es importante que lea el manual atentamente E...

Page 26: ...ta certificado 5 Conecte la bomba a su propio circuito designado s lo para la bomba sin ninguna otra carga en el circuito Las Figuras 3 4 y 5 muestras esquemas de cableado monof sicos y trif sicos 626...

Page 27: ...f brica Operaci n Riesgo de cuchilla y posibles arranques inesperados La rotaci n de la cuchilla con las manos en el rea de la cuchilla puede provocar la p rdida de los dedos Desconecte la corriente e...

Page 28: ...merja toda la bomba en una soluci n desinfectante lej a con cloro diluida al menos durante una hora antes de desarmarla 5 Usando un calibrador de comprobaci n mida el espacio libre de corte entre el r...

Page 29: ...s juntas del eje 9 Destornille cuatro tornillos de casquete y saque el soporte de la caja del motor 10 Use un destornillador de hoja plana y empuje cuidadosamente la mitad de la junta inferior para sa...

Page 30: ...tenga la bomba por un minuto m s o menos y vuelva a encenderla Repita este procedimiento de apagar y volver a encender hasta que se haya despejado la bolsa de aire Si el problema a n est presente DESC...

Page 31: ...Piezas de reparaci n 31 Piezas de reparaci n 6332 1110 1 2 8 3 4 7 6 3 5 3...

Page 32: ...43610 RP JP21454 RP JP40381 RP JP43696 RP JP21876 RP JP43868 RP JP43869 RP JP43870 G3D 21 G3D 03 RP JP43641 RP JP20875 RP JP43063 RP JP43699 RP JP43700 G3D 23 RP JP43909 G3D 43 RP JP43642 G5D 03 RP JP...

Page 33: ...la garant a Tambi n es importante indicar que los motores trif sicos deben estar protegidos por rel s de sobrecarga de disparo extra r pido de tres patas con compensaci n ambiental y del tama o recome...

Page 34: ...1 G2DT 03 378 4 14 9 221 9 8 73 103 4 06 217 1 8 55 136 5 5 37 349 5 13 76 G2DT 23 G2DT 43 G2D 01 417 16 42 247 9 72 123 4 84 254 5 10 02 141 5 55 387 15 24 G2D 21 G2D 03 378 4 14 9 221 9 8 73 103 4 0...

Page 35: ......

Page 36: ......

Reviews: