background image

Installation • Operation 

5

6.  use a control panel sized to match the pump. refer 

to control panel installation instructions for wiring 
connection information.

7.  Install the pump in accordance with all electrical 

codes that apply. Install a fused disconnect switch or 
circuit breaker in accordance with local codes.

8.  any alterations to internal pump circuitry must be 

made using crimp connectors and professional tools.

9.  the pump rotation must be clockwise (

 – viewed 

from the top of the pump). neVer operate the pump 
in reverse. 

 

If a three phase unit runs backwards, interchange 
two of the three power supply wires to reverse the 
motor’s direction of rotation.

Control Panels

 Risk of electrical shock . Ground pump 

and motor before connecting controls or power supply. 
adhere to local electrical codes governing pump and 
control installations.
a control panel is not included with the pump. Install 
a simplex or duplex control panel (purchase separately) 
for proper pump operation. single phase pumps require 
a start package, as shown in Product Specifications. a 
full range of controls and switches are available from 
your dealer.
If a Jung pumpen control panel is not used, install a 
control panel with circuit breaker or fused disconnect 
as required by local code. use magnetic starters with 
ambient compensated overload protection. three phase 
units require three line protection; single phase units 
require only one line protection. Inadequate protection 
voids the warranty.

Co ntrol Panel Overload Adjustment – 

Three Phase

NOTICE: see your con trol panel in stallation and 
operating instructions before adjusting overload setting.
set the overload protective device to the nameplate full 
load current. 
size the overload protective device so that the trip 
current is 115% of the nameplate full load current.

Operation

 Risk of cuts and possible unexpected starts . 

rotation of the cutter with hands in the cutter area can 
cause loss of fingers. disconnect the electrical power and 
keep your hands away from the pump inlet opening when 
working on or handling the pump for any reason. do not 
use automatic reset controls with this pump. 
single phase units have an automatic overload protector 
in the motor which will protect the motor from burning 
out due to overheating/overloading. When the motor 
cools down, the overload protector will automatically 
reset and start the motor. this can happen at any time.
three phase units require external overload protection.
If the overload trips frequently, check for the cause. It 
could be:
•  stuck impeller
•  wrong/low voltage
•  bad thermal overload protector
•  electrical failure in the motor. If the motor has 

electrically failed, replace the pump.

Grinder Assembly: the grinder unit consists of a 
cutting rotor and a cutting plate. persistent jamming 
and clogging of the pump indicates dull or worn 
grinder parts. If either the cutting rotor or plate is dull, 
replace both.
NOTICE: normal domestic sewage will cause very little 
dulling or wear of the pump parts. However, pumping 
abrasives (such as fine sand) will increase wear and 
tear and may make it necessary to replace the grinder 
assembly frequently.
the pump is not equipped with thermostats or a leak 
sensor probe. check the seal chamber oil condition 
quarterly in heavy duty service or annually in light 
duty service.
NOTICE: Failure to monitor the oil condition voids the 
warranty. Motors damaged by flooding of the motor 
cavity due to seal or o-ring failure may not be covered 
under warranty.
Verify the capacity of the pump by checking the 
discharge. Verify that the pump is free from any vibration 
and noise.
to avoid overheating the motor for continuous operation, 
the pump must be completely submerged in liquid. set 
the level switches to maintain this submerged condition. 
do not allow the pump to run in a dry sump. It will void 
the warranty and may damage the pump.

Summary of Contents for MULTICUT G2D-01

Page 1: ...ci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 800 642 5930 Espa ol Paginas 24 34 2012 JP913 01 24 12 Installation and Operator s Manual...

Page 2: ...ump s capacity electrical or mechanical failure in the pump etc may prevent your pump from functioning normally To prevent possible damage consult your dealer about installing a secondary sewage pump...

Page 3: ...r immediately Thank you for purchasing this Jung Pumpen product To help ensure years of trouble free operation please read the manual carefully This pump may be installed on an optional guide rail lif...

Page 4: ...e must be within 10 of the nameplate voltage If in doubt consult a licensed electrician 5 Connect the pump to its own dedicated circuit with no other load on the circuit Figures 3 4 5 show single and...

Page 5: ...nd possible unexpected starts Rotation of the cutter with hands in the cutter area can cause loss of fingers Disconnect the electrical power and keep your hands away from the pump inlet opening when w...

Page 6: ...sk of infection Pathogens such as hepatitis can collect on pump during normal operation Submerge the complete pump in a disinfectant solution dilute chlorine bleach for at least one hour before disass...

Page 7: ...e motor shaft If necessary use a flat blade screwdriver to help pry the seals from the shaft 9 Unscrew four capscrews and remove the bracket from the motor housing 10 Use a flat blade screwdriver and...

Page 8: ...uously Liquid level control cords tangled Untangle cords for free operation Pump is airlocked Stop pump for about one minute then restart Repeat stopping and starting until the airlock clears If the a...

Page 9: ...Repair Parts 9 Repair Parts 6332 1110 1 2 8 3 4 7 6 3 5 3...

Page 10: ...3907 G2DT 43 RP JP43638 G3D 01 RP JP43652 RP JP43610 RP JP21454 RP JP40381 RP JP43696 RP JP21876 RP JP43868 RP JP43869 RP JP43870 G3D 21 G3D 03 RP JP43641 RP JP20875 RP JP43063 RP JP43699 RP JP43700 G...

Page 11: ...erating a three phase motor with single phase power through a phase converter will void the warranty Note also that three phase motors must be protected by three leg ambient compensated extra quick tr...

Page 12: ...8 4 14 9 221 9 8 73 103 4 06 217 1 8 55 136 5 5 37 349 5 13 76 G2DT 23 G2DT 43 G2D 01 417 16 42 247 9 72 123 4 84 254 5 10 02 141 5 55 387 15 24 G2D 21 G2D 03 378 4 14 9 221 9 8 73 103 4 06 217 1 8 55...

Page 13: ...ous aupr s de votre d taillant concernant l installation d une deuxi me pompe d eaux d gout ou d une alarme de niveau lev de l eau Consultez la section D pannage de ce manuel pour obtenir des renseign...

Page 14: ...transporteur Nous vous remercions d avoir achet ce produit Jung Pumpen Pour vous assurer des ann es de fonctionnement sans probl me veuillez lire ce manuel attentivement Cette pompe peut tre mont e s...

Page 15: ...En cas de doute consultez un lectricien agr 5 Raccordez la pompe son propre circuit d di sans aucune autre charge sur celui ci Les figures 3 4 et 5 repr sentent des sch mas de c blage monophas et trip...

Page 16: ...e signal tique Utilisation Dilac rateur dangereux et ventuels d marrages inopin s Si vos mains se trouvent dans la zone de rotation du dilac rateur lorsque celui ci tourne vous risquez de perdre des d...

Page 17: ...aient se d poser sur la pompe lors de son fonctionnement normal Plongez compl tement la pompe dans une solution d sinfectante base d agent de blanchiment dilu pendant au moins une heure avant de la d...

Page 18: ...de l arbre 9 D vissez quatre vis d assemblage et retirez le support du carter du moteur 10 Utilisez un tournevis lame plate et d gagez tr s pr cautionneusement la moiti de joint inf rieure de la cavit...

Page 19: ...rement La pompe est bloqu e par de l air Arr tez la pompe pendant une minute environ puis red marrez la R p tez l arr t et le d marrage jusqu ce que le blocage par l air soit limin Si le blocage persi...

Page 20: ...Pi ces de rechange Pi ces de rechange 20 6332 1110 1 2 8 3 4 7 6 3 5 3...

Page 21: ...G3D 01 RP JP43652 RP JP43610 RP JP21454 RP JP40381 RP JP43696 RP JP21876 RP JP43868 RP JP43869 RP JP43870 G3D 21 G3D 03 RP JP43641 RP JP20875 RP JP43063 RP JP43699 RP JP43700 G3D 23 RP JP43909 G3D 43...

Page 22: ...galement que les moteurs triphas s doivent tre prot g s par des relais de surcharge thermocompens s tripolaires d clenchement ltrarapide du calibre recommand ou la garantie sera nulle Votre seul recou...

Page 23: ...T 03 378 4 14 9 221 9 8 73 103 4 06 217 1 8 55 136 5 5 37 349 5 13 76 G2DT 23 G2DT 43 G2D 01 417 16 42 247 9 72 123 4 84 254 5 10 02 141 5 55 387 15 24 G2D 21 G2D 03 378 4 14 9 221 9 8 73 103 4 06 217...

Page 24: ...ionario sobre la posibilidad de instalar una segunda bomba cloacal o una alarma de alto nivel de agua Consulte la secci n de Localizaci n de fallas en este manual para obtener informaci n sobre los pr...

Page 25: ...mediatamente una reclamaci n a la empresa de transporte Gracias por su compra de este producto Jung Pumpen Para garantizar a os de operaci n sin problemas es importante que lea el manual atentamente E...

Page 26: ...ta certificado 5 Conecte la bomba a su propio circuito designado s lo para la bomba sin ninguna otra carga en el circuito Las Figuras 3 4 y 5 muestras esquemas de cableado monof sicos y trif sicos 626...

Page 27: ...f brica Operaci n Riesgo de cuchilla y posibles arranques inesperados La rotaci n de la cuchilla con las manos en el rea de la cuchilla puede provocar la p rdida de los dedos Desconecte la corriente e...

Page 28: ...merja toda la bomba en una soluci n desinfectante lej a con cloro diluida al menos durante una hora antes de desarmarla 5 Usando un calibrador de comprobaci n mida el espacio libre de corte entre el r...

Page 29: ...s juntas del eje 9 Destornille cuatro tornillos de casquete y saque el soporte de la caja del motor 10 Use un destornillador de hoja plana y empuje cuidadosamente la mitad de la junta inferior para sa...

Page 30: ...tenga la bomba por un minuto m s o menos y vuelva a encenderla Repita este procedimiento de apagar y volver a encender hasta que se haya despejado la bolsa de aire Si el problema a n est presente DESC...

Page 31: ...Piezas de reparaci n 31 Piezas de reparaci n 6332 1110 1 2 8 3 4 7 6 3 5 3...

Page 32: ...43610 RP JP21454 RP JP40381 RP JP43696 RP JP21876 RP JP43868 RP JP43869 RP JP43870 G3D 21 G3D 03 RP JP43641 RP JP20875 RP JP43063 RP JP43699 RP JP43700 G3D 23 RP JP43909 G3D 43 RP JP43642 G5D 03 RP JP...

Page 33: ...la garant a Tambi n es importante indicar que los motores trif sicos deben estar protegidos por rel s de sobrecarga de disparo extra r pido de tres patas con compensaci n ambiental y del tama o recome...

Page 34: ...1 G2DT 03 378 4 14 9 221 9 8 73 103 4 06 217 1 8 55 136 5 5 37 349 5 13 76 G2DT 23 G2DT 43 G2D 01 417 16 42 247 9 72 123 4 84 254 5 10 02 141 5 55 387 15 24 G2D 21 G2D 03 378 4 14 9 221 9 8 73 103 4 0...

Page 35: ......

Page 36: ......

Reviews: