background image

Safety 2

Important Safety Instructions

SAVE THESE INSTRUCTIONS - this manual contains 
important instructions that should be followed during 
installation, operation, and maintenance of the product. 
save this manual for future reference.

 this is the safety alert symbol. When you see this 

symbol on your pump or in this manual, look for one of 
the following signal words and be alert to the potential 
for personal injury!

 indicates a hazard which, if not avoided, will 

result in death or serious injury.

 indicates a hazard which, if not avoided, 

could result in death or serious injury.

 indicates a hazard which, if not avoided, 

could result in minor or moderate injury.
NOTICE addresses practices not related to personal injury.
the manufacturer cannot anticipate every possible 
circumstance that might involve a hazard. the warnings 
in this manual, and the tags and decals affixed to the unit 
are, therefore, not all-inclusive. If you use a procedure 
or operating technique that the manufacturer does not 
specifically recommend, you must satisfy yourself that it 
is safe for you and others. you must also make sure that 
the procedure or operating technique that you choose 
does not render the system unsafe.
electrically powered sewage pumps normally give many 
years of trouble-free service when correctly installed, 
maintained, and used. However, unusual circumstances 
(interruption of power to the pump, large solids in 
the sump, flooding that exceeds the pump’s capacity, 
electrical or mechanical failure in the pump, etc.) may 

prevent your pump from functioning normally. to prevent 
possible damage, consult your dealer about installing 
a secondary sewage pump or a high water alarm. see 
Troubleshooting in this manual for information about 
common sewage pump problems and remedies. For 
more information, see your retailer, call Jung pumpen 
customer service at 1-800-642-5930 or visit our web site 
at jungpumpen-us.com.

 Risk of electrical shock . shock can cause 

serious injury or death. Failure to follow the warnings 
below can result in fatal electric shock.

 Risk of electrical shock . during operation 

the pump is in water:
•  Check your local codes before installing. You 

must comply with their rules. only qualified 
personnel should install the pump and associated 
control equipment.

•  Ground the pump according to all applicable codes 

and ordinances.

•  Take care when changing fuses or resetting the 

circuit breaker. disconnect power to the pump 
before servicing. do not stand in water when 
working on the control box or with the circuit 
breaker panel.

•  This pump is intended for permanent connection 

only. do not connect conduit to pump. provide a 
strain relief at the control box for the power supply 
cord connection to box. all control components 
must be ul or csa listed and suitable for end use 
application.

•  Do not remove cord or strain relief. Do not lift the 

pump by the power cord (see Cord Lift Warning). 

Contents

Important Safety Instructions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .2
Installation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .3

Electrical   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Control Panels    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5

Operation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .5
Maintenance  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .6

Seal Lubrication  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

Troubleshooting    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .8
Repair Parts   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .9
Product Specifications    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .11
Warranty   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .11

Summary of Contents for MULTICUT G2D-01

Page 1: ...ci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 800 642 5930 Espa ol Paginas 24 34 2012 JP913 01 24 12 Installation and Operator s Manual...

Page 2: ...ump s capacity electrical or mechanical failure in the pump etc may prevent your pump from functioning normally To prevent possible damage consult your dealer about installing a secondary sewage pump...

Page 3: ...r immediately Thank you for purchasing this Jung Pumpen product To help ensure years of trouble free operation please read the manual carefully This pump may be installed on an optional guide rail lif...

Page 4: ...e must be within 10 of the nameplate voltage If in doubt consult a licensed electrician 5 Connect the pump to its own dedicated circuit with no other load on the circuit Figures 3 4 5 show single and...

Page 5: ...nd possible unexpected starts Rotation of the cutter with hands in the cutter area can cause loss of fingers Disconnect the electrical power and keep your hands away from the pump inlet opening when w...

Page 6: ...sk of infection Pathogens such as hepatitis can collect on pump during normal operation Submerge the complete pump in a disinfectant solution dilute chlorine bleach for at least one hour before disass...

Page 7: ...e motor shaft If necessary use a flat blade screwdriver to help pry the seals from the shaft 9 Unscrew four capscrews and remove the bracket from the motor housing 10 Use a flat blade screwdriver and...

Page 8: ...uously Liquid level control cords tangled Untangle cords for free operation Pump is airlocked Stop pump for about one minute then restart Repeat stopping and starting until the airlock clears If the a...

Page 9: ...Repair Parts 9 Repair Parts 6332 1110 1 2 8 3 4 7 6 3 5 3...

Page 10: ...3907 G2DT 43 RP JP43638 G3D 01 RP JP43652 RP JP43610 RP JP21454 RP JP40381 RP JP43696 RP JP21876 RP JP43868 RP JP43869 RP JP43870 G3D 21 G3D 03 RP JP43641 RP JP20875 RP JP43063 RP JP43699 RP JP43700 G...

Page 11: ...erating a three phase motor with single phase power through a phase converter will void the warranty Note also that three phase motors must be protected by three leg ambient compensated extra quick tr...

Page 12: ...8 4 14 9 221 9 8 73 103 4 06 217 1 8 55 136 5 5 37 349 5 13 76 G2DT 23 G2DT 43 G2D 01 417 16 42 247 9 72 123 4 84 254 5 10 02 141 5 55 387 15 24 G2D 21 G2D 03 378 4 14 9 221 9 8 73 103 4 06 217 1 8 55...

Page 13: ...ous aupr s de votre d taillant concernant l installation d une deuxi me pompe d eaux d gout ou d une alarme de niveau lev de l eau Consultez la section D pannage de ce manuel pour obtenir des renseign...

Page 14: ...transporteur Nous vous remercions d avoir achet ce produit Jung Pumpen Pour vous assurer des ann es de fonctionnement sans probl me veuillez lire ce manuel attentivement Cette pompe peut tre mont e s...

Page 15: ...En cas de doute consultez un lectricien agr 5 Raccordez la pompe son propre circuit d di sans aucune autre charge sur celui ci Les figures 3 4 et 5 repr sentent des sch mas de c blage monophas et trip...

Page 16: ...e signal tique Utilisation Dilac rateur dangereux et ventuels d marrages inopin s Si vos mains se trouvent dans la zone de rotation du dilac rateur lorsque celui ci tourne vous risquez de perdre des d...

Page 17: ...aient se d poser sur la pompe lors de son fonctionnement normal Plongez compl tement la pompe dans une solution d sinfectante base d agent de blanchiment dilu pendant au moins une heure avant de la d...

Page 18: ...de l arbre 9 D vissez quatre vis d assemblage et retirez le support du carter du moteur 10 Utilisez un tournevis lame plate et d gagez tr s pr cautionneusement la moiti de joint inf rieure de la cavit...

Page 19: ...rement La pompe est bloqu e par de l air Arr tez la pompe pendant une minute environ puis red marrez la R p tez l arr t et le d marrage jusqu ce que le blocage par l air soit limin Si le blocage persi...

Page 20: ...Pi ces de rechange Pi ces de rechange 20 6332 1110 1 2 8 3 4 7 6 3 5 3...

Page 21: ...G3D 01 RP JP43652 RP JP43610 RP JP21454 RP JP40381 RP JP43696 RP JP21876 RP JP43868 RP JP43869 RP JP43870 G3D 21 G3D 03 RP JP43641 RP JP20875 RP JP43063 RP JP43699 RP JP43700 G3D 23 RP JP43909 G3D 43...

Page 22: ...galement que les moteurs triphas s doivent tre prot g s par des relais de surcharge thermocompens s tripolaires d clenchement ltrarapide du calibre recommand ou la garantie sera nulle Votre seul recou...

Page 23: ...T 03 378 4 14 9 221 9 8 73 103 4 06 217 1 8 55 136 5 5 37 349 5 13 76 G2DT 23 G2DT 43 G2D 01 417 16 42 247 9 72 123 4 84 254 5 10 02 141 5 55 387 15 24 G2D 21 G2D 03 378 4 14 9 221 9 8 73 103 4 06 217...

Page 24: ...ionario sobre la posibilidad de instalar una segunda bomba cloacal o una alarma de alto nivel de agua Consulte la secci n de Localizaci n de fallas en este manual para obtener informaci n sobre los pr...

Page 25: ...mediatamente una reclamaci n a la empresa de transporte Gracias por su compra de este producto Jung Pumpen Para garantizar a os de operaci n sin problemas es importante que lea el manual atentamente E...

Page 26: ...ta certificado 5 Conecte la bomba a su propio circuito designado s lo para la bomba sin ninguna otra carga en el circuito Las Figuras 3 4 y 5 muestras esquemas de cableado monof sicos y trif sicos 626...

Page 27: ...f brica Operaci n Riesgo de cuchilla y posibles arranques inesperados La rotaci n de la cuchilla con las manos en el rea de la cuchilla puede provocar la p rdida de los dedos Desconecte la corriente e...

Page 28: ...merja toda la bomba en una soluci n desinfectante lej a con cloro diluida al menos durante una hora antes de desarmarla 5 Usando un calibrador de comprobaci n mida el espacio libre de corte entre el r...

Page 29: ...s juntas del eje 9 Destornille cuatro tornillos de casquete y saque el soporte de la caja del motor 10 Use un destornillador de hoja plana y empuje cuidadosamente la mitad de la junta inferior para sa...

Page 30: ...tenga la bomba por un minuto m s o menos y vuelva a encenderla Repita este procedimiento de apagar y volver a encender hasta que se haya despejado la bolsa de aire Si el problema a n est presente DESC...

Page 31: ...Piezas de reparaci n 31 Piezas de reparaci n 6332 1110 1 2 8 3 4 7 6 3 5 3...

Page 32: ...43610 RP JP21454 RP JP40381 RP JP43696 RP JP21876 RP JP43868 RP JP43869 RP JP43870 G3D 21 G3D 03 RP JP43641 RP JP20875 RP JP43063 RP JP43699 RP JP43700 G3D 23 RP JP43909 G3D 43 RP JP43642 G5D 03 RP JP...

Page 33: ...la garant a Tambi n es importante indicar que los motores trif sicos deben estar protegidos por rel s de sobrecarga de disparo extra r pido de tres patas con compensaci n ambiental y del tama o recome...

Page 34: ...1 G2DT 03 378 4 14 9 221 9 8 73 103 4 06 217 1 8 55 136 5 5 37 349 5 13 76 G2DT 23 G2DT 43 G2D 01 417 16 42 247 9 72 123 4 84 254 5 10 02 141 5 55 387 15 24 G2D 21 G2D 03 378 4 14 9 221 9 8 73 103 4 0...

Page 35: ......

Page 36: ......

Reviews: