136
1) Confirm that the sewing machine has stopped,
and turn OFF the power with the power switch.
2) Confirm that the power switch has been turned
OFF, and draw out the power cord from the power
receptacle. Then, wait for five minutes or more.
3) Remove four screws tightening the rear cover
of the electrical box and slowly remove the rear
cover.
4) Hold the glass portion of the fuse to be replaced
and remove the fuse.
5) Use the fuse with the specified capacity.
1
2A / 250V Time-lag type (HF0078020P0)
2
10A / 250V Time-lag type (HF001301000)
9. MaINtENaNcE
WarNING :
to prevent personal injuries caused by electric shock hazards or abrupt start of the sewing machine,
carry out the work after turning oFF the power switch and ascertaining that the motor has completely
stopped. to prevent personal injuries, when a fuse has blown out, be sure to replace it with a new
one with the same capacity after turning oFF the power switch and removing the cause of the blown-
out of the fuse.
9-1. replacing the power fuse
w
w
q