– 6 –
WARNING :
To protect against possible personal injury due to abrupt start of the machine, be sure to start the
following work after turning the power off and ascertaining that the motor is at rest.
2-4. Pneumatic components (Only for the models provided with the stitch skipping
detecting device and bobbin-thread remaining amount detecting device)
(1) Installing the regulator
1) Install regulator (asm.)
❶
on mounting plate
❺
with screw
❷
, spring washer
❸
and nut
❹
which are supplied with the unit.
2) Attach joint
❻
to inlet
1
. Attach joint
❼
to out-
let
2
.
3) Attach mounting plate
❺
on the undersurface of
the table with accessory screws
❽
supplied with
the plate.
4) Connect branch Y union
❾
to joint
❼
.
* Screw
❷
which is supplied with the unit:
Thread diameter M5; Length: 12 mm
(SM6051202TP)
* Branch Y union
❾
(PJ308060004) which comes
with the air blower solenoid valve asm._SD
should be used.
❶
❷
A
(2) Adjusting the air pressure
1) The operating air pressure is 0.5 to 0.55 MPa.
Adjust the air pressure using air pressure regu-
lating knob
❶
of the filter regulator.
2) In the case fluid accumulation is observed in
A
section of the filter regulator, turn drain cock
❷
to drain the fluid.
Decrease
Increase
❷
❶
❺
❼
❻
❹
❸
❽
1
2
❾