– 77 –
(2) Setting items for the polygonal-shape stitching steps
Data No.
Item name
Unit of
change
Input range
Step 01
S201
Step changeover
: Number of stitches
: One-touch switch
: Multi-layered part
S203
Sensor value to change over the
step
1
1000 to 3000
S204
Number of stitches
(seam length in mm)
1 stitch
1 to 10000
S205
Stitch length
(the number of stitches per inch, the
number of stitches per 3 cm)
0.1 mm
-9.0 to 9.0 / Custom pitch No.1 to 20
S206
Needle thread tension, left
1
0 to 140
S207
Needle thread tension, right
1
0 to 140
S208
Alternating vertical movement
amount
0.5 mm
0.5 to 9.0
S209
Presser foot pressure
1
-20 to 200
S210
Suspended ruler position
0.1 mm
0.0 to 60.0
S211
Needle bar stop position at the time
of pause
:
Stop with the needle up
:
Stop with the needle down
S212
Needle entry alignment position of
the needle bar
:
OFF
:
ON
S213
Presser foot lifting during
intermediate stop:
0.5 mm
0.0 to 20.0