98
−
Trouble
Cause (1)
Cause (2)
Checking order and adjusting procedure
Page
10.
Error No. 10
Temporary stopping
11
.
Error No. 11
Speed detection error
12
.
Error No. 12
Needle UP error
1
.
State that temporary stop switch
is pressed is detected.
2
.
When 2-pedal system is used,
starting switch has been turned
OFF during running.
1
.
Abnormal speed of rotation is
detected.
1
.
The sewing machine has not
stopped at the section of UP stop
position.
1.
Temprary stop switch is pressed.
2
.
Connection is defective or cable
is defective.
3
.
Temporary stop switch is
defective.
1
.
Assembling of starting switch is
wrong.
2
.
Connection is defective or cable
is defective.
1
.
Connection of SDC•I/F cable is
defective or cable is defective.
2
.
Connection of UP position
detecting cord is defective or
cable is defective.
3
.
Connection of encoder cable is
defective or cable is defective.
4.
Failure with SDC circuit board
1.
Stop position is changed.
Press reset key, or press again the temporary stop switch to release.
Check the connection of CN23 and CN58.
Replace the temporary stop switch.
Check the assembling of the starting switch.
Check the connection of CN18 and CN65.
Check the connection of CN12 and CN40.
Check the connection of CN44 and CN114.
Check the connection of CN43.
When servo motor error is not displayed and the error No. 11 is
displayed again, replace the SDC circuit board.
Turn up to UP stop position with the hand pulley.