93
−
Trouble
Cause (1)
Cause (2)
Checking order and adjusting procedure
Page
2
.
Sewing LED fails to light even when
pressing the ready key.
3.
Error No. 1
Servo motor error
From the previous page
2
.
Signal is not transferred to the
operation panel.
3
.
DC+5V is not supplied to MAIN
circuit board.
1.
Set ready state is not completed.
2.
Sewing LED fails to light.
1.
Servo motor error E 1
Motor lock
2.
Servo motor error E 2
Upper dead point sensor is
defective.
1
.
Connection is defective or cable
is defective.
2.
Failure with MAIN circuit board
1.
Failure with SDC circuit board
1
.
Signal is not transferred from SDC
circuit board.
1.
Failure with the sewing LED
2
.
Connection is defective or cable
is defective.
1
.
Sewing machine lock or heavy
load
1
.
UP position signal is not
transferred even when the sewing
machine runs.
2.
Failure with SDC circuit board
3
.
Connection is defective or cable
is defective.
Check the connection of CN17, CN41 and CN44.
Perform the aforementioned check, and replace MAIN circuit board if
there is no trouble.
Draw out CN12, and replace SDC circuit board if the voltage of Nos. 1
to 34 pins on the cable side is not DC+5V.
When panel operation or pedal operation is not accepted, signal from
SDC circuit board is not transferred. Replace the SDC circuit board.
When the starting switch is accepted, replace the operation box.
Replace the operation box.
Check the driving system.
Measure the voltage between Nos. 2 to 3 pins of CN44. When the
voltage does not change over HIGH/LOW even by turning the main
shaft by hand and moving sensor slit to and fro, replace the UP position
detecting sensor.
When the signal from the sensor changes over HIGH/LOW, replace
the SDC circuit board.
Check the connection of CN44 and CN114.
To the next page