102
−
Trouble
Cause (1)
Cause (2)
Checking order and adjusting procedure
Page
29. Parameter cannot be changed.
30. Sewing shape cannot be obtained.
1.
Panel switch fails to work.
1.
Step-out of stepping motor
2
.
Presser or needle bar fails to
work.
1
.
Connection is defective or cable
is defective.
2
.
One or several places fail to work.
3
.
Parameter only cannot be
changed.
4.
All places cannot accept.
1.
Load is heavy.
2
.
Connection is defective or cable
is defective.
3.
Stepping motor is defective.
4.
Failure with MAIN circuit board
1.
Assembling is wrong.
Check the connection of CN41, CN42, CN43 and CN17. Check the
insertion only of CN42 and CN43 in operation box and do not draw or
insert them since the surface coat carbon on them will be taken off and
defective contact will result.
Panel sheet is defective. Replace the operation box.
Memory switch is set to the prohibition of change of parameter.
Operation box is defective.
Check the assembling.
Check the connection of CN14, CN15, CN16, CN51, CN52 and CN53.
Resistance of each phase of any stepping motor is approximately 1
Ω
.
However, the actual observation shows approximately 1.2 to 1.5
Ω
according to wire resistance, contact resistance, etc. Check the
resistance value referring to the circuit diagram.
Check according to the aforementioned items.
Replace the MAIN circuit board unless the fuse has blown out.
Check the assembling.
Summary of Contents for LBH-1700
Page 1: ...R ENGINEER S MANUAL 29339504 No 04 Electronic Buttonholing Machine LBH 1700 Series ...
Page 55: ... 51 MEMO ...