Jetter AG
Technical specifications | 4
User Manual – JXM-IO-E30
20 / 70
Digital inputs
All digital inputs are PNP inputs. From HW revision 02.00 onwards, digital input
DI_P_1 can also be configured as NPN input.
All outputs can also be used as simple digital NPN or PNP inputs with restric-
tions.
Parameter
Description
Digital inputs with frequency measurement
Abbreviation
DI_P
Quantity
4
Pull-down resistor
5.6 kΩ
H level
≥ 4.6 V
L level
≤ 1.6 V
Input frequency
0.1 Hz … 10 kHz
Dielectric strength
Max. +32 V
Tab. 19:
Digital inputs DI_P_1 ... DI_P_4
Configuration
inputs
Configuration inputs are tristate inputs and are used to set the node ID. The base
address can be set by the user and has the default value 0x30. The node ID can
be shifted by connecting the configuration inputs with VBAT_ECU or GND via an
offset.
Parameter
Description
Configuration inputs for configuring the node ID
Abbreviation
CFG1
CFG2
Quantity
2
Tab. 20:
Configuration inputs CFG1 … CFG2