Jetter AG
Product Description | 3
User Manual – JXM-IO-E30
10 / 70
3.3 Product features
■
1 CAN port with optional terminating resistor
■
Communication via CANopen protocol
■
8 analog inputs for current or voltage measurement
■
4 digital inputs for use as digital, frequency, period time or counter inputs
■
4 digital outputs with current monitoring. 3 A maximum load per channel.
The total current must not exceed 6 A. These outputs can also be used as
digital inputs.
■
6 PWM outputs, 7 A max., with current monitoring. These outputs can also be
used as digital inputs.
■
4 PWM outputs, 3 A max., with precision current measurement and PID
current control. These outputs can also be used as digital inputs.
■
3 outputs with monitored supply voltages for sensors (battery voltage)
■
Separate connections for logic and output driver supply
■
Total current output of up to 25 A
3.4 Diagnostic capability via LEDs
The JXM-IO-E30 is equipped with 2 LEDs to indicate various states and errors.
Color
Blinking pattern
Description
Red
Permanently ON
■
Operating voltage is present
(VBAT_ECU).
■
The boot loader is not running.
Red
Steady
200 ms
■
The boot loader is running.
■
The device has no firmware.
OFF
200 ms
Red
Steady
400 ms
■
The start process was completed without
errors.
■
The device is in the
Stopped
state.
OFF
400 ms
Green
Steady
200 ms
■
The start process was completed without
errors.
■
The device is in the
Pre-Operational
state.
OFF
200 ms
Green
Steady
200 ms
■
The start process was completed without
errors.
■
The device is in the
Operational
state.
OFF
600 ms
Green
3x
ON/
OFF
200 ms
■
The start process was completed without
errors.
■
The device is in calibration mode.
Break
400 ms
Red
Steady
200 ms
■
The device is in the
Bus Off
state.
■
Bus communication is not possible.
■
There is a wiring error.
OFF
400 ms
Green
Steady
200 ms
OFF
400 ms