Parameterization | 8
User Manual – JXM-IO-E30
45 / 70
8.2 Setting the node ID
The base node ID can be set in the
The configuration inputs (CFG1 and CFG2) generate an offset to the set base node ID.
CFG1 and CFG2 may have one of the following 3 states:
■
Jumpered to GND → Low (L)
■
Jumpered to VBAT → High (H)
■
Open → O
The offset corresponds to the values in the following table:
CFG1
CFG2
Offset of module ID
O
O
0
L
O
1
H
O
2
O
L
3
L
L
4
H
L
5
O
H
6
L
H
7
H
H
8
Tab. 37:
Offset for set base node ID
8.3 Diagnostic information
Diagnostic information
Index
Subindex
Description
Type
Types of
access
Unit
0x2000
0
Number of supported entries
U8
R
2
VBAT_PWR
U16
R
mV
3
7V IO
U16
R
mV
4
3V3
U16
R
mV
6
PCB temperature
I16
R
0.1 °C
7
CPU temperature
I16
R
0.1 °C
9
CPU VRef
U16
R
mV
10
SPWR1
U16
R
mV
11
SPWR2
U16
R
mV
12
SPWR3
U16
R
mV
13
VBAT_ECU
U16
R
mV
14
CFG1
U16
R
mV
15
CFG2
U16
R
mV
20
Total current ±50 %
U32
R
mA
Tab. 38:
Diagnostic information