12
3
Hardware and Installation
3.1
Environmental Conditions
Storage and transport
No outdoor storage. Warehouses have to be well
ventilated and dry. Temperature from
-25°C up to +55°C
Temperature while operating 5°C -50°C environment,
(above 40°C, nominal current reduced to 6A)
Humidity while operating 10-90% non-condensing
Air conditioning
No external air conditioning needed; integrated heat
sink.
3.2
Assembly and Installation
Assembly with two screws on an electrically
conductive rear wall e.g. the back wall of a switch
cabinet.
For a series mounting, the devices can be mounted
directly next to each other. A distance of more than
1mm between the devices, which is advantageous for
the removal and mounting of a device, is not
necessary.
The distance to the base plate must be at least
40mm.
We recommend mounting the devices in vertical
orientation with the 7-segment display at the top to
ensure a good cooling air circulation.
Where space is limited:
Package with 5 XENAX® Servo controllers mounted on
a base plate with a common connection for the
power supply.
When operating with a power supply motor above
60VDC, the XENAX® Servo controller must be
mounted in an electrical control cabinet and the
XENAX® Servo controller must be connected to
protective earth using the shielding clamp (Art. No.
130.09.00) for motor cable.
When operating with a power supply motor below
or equal 60VDC, a SELV/PELV power supply has to
be used or XENAX® Servo controller must be
connected to protective earth using the shielding
clamp (Art. No. 130.09.00) for motor cable.