Installation and Operating Instructions ECOVARIO® 616, 616 D
70
Subject to change without notice!
All cases on the left side below the characteristics in fi g. 9.3 are covered by the ballast resistors DPRxx-200
abgedeckt werden.
Frame conditions:
Basis is the normal cycle time of 120 s. Th e casing temperature be determined with the temperature diagram
in fi g. 9.4 on the basis of the average power. Th e avarage power is calculated according to formula (4). Th e
value taken from fi g. 9.4 plus 5 K amounts to the casing temperature at the chosen poulse strength.
Fig. 9.4: Housing temperature ballast resistor DPRxx-200 at CDF = 100 %, max. T = 250 °C
9.3
Mating connector sets
Mating connetor sets for all interfaces of the ECOVARO® is available. All mating connectors are clearly la-
belled and designed in a way that there is no danger of mixing them up.
Table 9.2: Composition of ECOVARIO® 616 D mating connector set DHK10
Connector Function
Mating connector designation, Phoenix ID No.
Number
X1A, X1B
24 V/digital inputs and outputs
Combicon MC 1,5/8-ST-3,81 CN 2,7 BDNZX1,
No. 17 55 40 2
2
X2A, X2B
Digital inputs
Combicon MC 1,5/ 8-ST-3,81, CN 1,8 BDNZX2,
No. 17 55 41 5
2
X8A, X8B
STO function
MC 1,5/ 4-ST-3,81, BD: 1-4, No. 18 40 72 2
2
X6
Power connection
GMSTB 2,5 HCV/ 4-ST-7,62, No. 17 14 29 4
1
X7A, X7B
Motor brake
ZEC1,0/3-ST-3,5 C1,3R1,3 No. 19 98 20 5
2
X5A, X5B
Motor connection
GIC 2,5 HCV/ 4-ST-7,62, No. 17 45 64 5
2
X4
DC link / ballast resistor
GIC 2,5 HCV/ 5-ST-7,62, No. 17 45 65 8