Installation and Operating Instructions ECOVARIO® 616, 616 D
16
Subject to change without notice!
4.3
General technical data
Table 4.3: General technical data, control signals
No.
Control signal
Unit
616 A
616 D
1
1
24 V supply (current draw
without outputs)
V
24 ±10 %
A
0.8
8
16
Digital control signal inputs
V
0 ... 36 (Switching level: L->H: 11 V; H->L: 7 V
acc. to IEC 61131-2 type 3)
mA
10 (at 24 V)
3
6
Digital control signal outputs
V
24
A
0.5
Table 4.4: General technical data, external fuses
616 AR
616 DR
AC supply
16 A (characteristic C)
16 A (characteristic C)
Note: When the device is used in an UL environment the overcurrent protection equipment has
to comply to UL489 (current ≤ 13 A) or UL Class CC (current ≤ 15 A, time delay current limiting)!
Alternatively a motor protection switch (self protecting motor controller, certified acc. to UL508,
type E) can be used.
24 V supply
max. 12 A (fast)
external ballast resistance (not accessory resistors
DPRxx-xxx)
1)
t.b.d.
t.b.d.
1) The accessory ECOVARIO
®
resistors DPRxx-xxx are intrinsically safe and therefore do not have to be fused.
Table 4.5: General technical data, ambient conditions
Ambient conditions
ECOVARIO® is designed for ambient conditions of class 3K3 following EN 50178.
Symb.
Condition
Unit
T
A
Ambient temperature during
operation with nominal load
°C
5 – 40
Degree of humidity (not con-
densing)
% R. H.
5 – 85
p
Air pressure
mbar
860 – 1 060
Cooling
the closed cubicle has to be sufficiently ven-
tilated.
h
Installation altitude
m
up to 1 000 without restriction of power
Installation position
The technical data refer to a vertical position.
Protection class
IP20
Table 4.6: General technical data, dimensions and weight
Dimensions and weight
Unit
ECOVARIO® 616
Dimensions w x h x d
mm
82 x 330 x 225
Weight of unit
kg
4.0