Chapter 7 Automated RFC 2544 Testing
Running the Expert RFC 2544 test
216
HST-3000 Ethernet Testing User’s Guide
6 Specify the following settings as appropriate for your test:
).
“Configuring layer 3 IP tests” on
).
c Layer 4 Settings (See
“Configuring layer 4 traffic” on
).
7 Use the left or right arrow key to go to the Test Selections,
Test Selections (Upstrm) or Test Selections (Dnstrm)
configuration menu, and then Enable the tests you want
to run. You must enable the Throughput test to enable the
Latency (RTD), System Recovery, and Packet Jitter tests.
If you are running the test in Asym (Combined) mode,
Test Selection menus appear for both upstream and
downstream tests.
8 Specify the maximum bandwidth to transmit during the
course of each of the enabled tests.
NOTE: RFC 2544 tests always transmit a constant load of
traffic.
Remote IP
If you are running the test with
layer 2 traffic, specify the remote IP
address for the instrument on the
far end.
Source IP
If you are running the test with
layer 2 traffic, specify the source IP
address for your instrument.
Default Gateway
If you are running the test with layer
2 traffic, specify default gateway.
Subnet Mask
If you are running the test with layer
2 traffic, specify subnet mask.
Setting
Parameter
Summary of Contents for IP Video Test Option HST-3000
Page 1: ...HST 3000 Ethernet Testing User s Guide ...
Page 2: ......
Page 22: ...About This Guide Conventions xx HST 3000 Ethernet Testing User s Guide ...
Page 138: ...Chapter 3 Ethernet Testing MAC in MAC testing 116 HST 3000 Ethernet Testing User s Guide ...
Page 202: ...Chapter 5 TCP UDP Testing Loopback testing 180 HST 3000 Ethernet Testing User s Guide ...
Page 278: ...Chapter 9 Troubleshooting Resolving problems 256 HST 3000 Ethernet Testing User s Guide ...
Page 346: ...Glossary 324 HST 3000 Ethernet Testing User s Guide ...
Page 354: ...Index 332 HST 3000 Ethernet Testing User s Guide ...
Page 355: ......