Chapter 8
FiberComplete Modules
Configuring the units
User Manual
770000102/08
113
Yes
: the fiber length will be measured.
No
: the fiber length will not be measured during
the test.
OTDR Measurement
select the measurement method for OTDR.
OTDR Measurement
select the measurement
method for OTDR.
None.
: OTDR measurement is not performed
after FiberComplete test.
Unidir.
: OTDR measurement is performed in one
way: from the primary unit toward the secondary
one.
Bidir.
: OTDR measurement is performed with
parameters defined in automatic mode in the two
ways: from primary to seconday unit, and from
secondary to primary unit.
OTDR Acquisition
if OTDR measurement is configured with
Unidir
or
Bidir
parameter, select the acquisition mode
for OTDR.
Auto.
: OTDR acquisition is performed with
parameters defined in automatic mode.
Manual
; OTDR measurement is performed with
the parameters manually defined in the OTDR
Setup menu (see
No
: OTDR measurement is not performed.
Fault Finder
select if Fault Finder function must be activated.
Yes
: if a result for Loss and/or ORL exceeds one
limit value defined in the
Thresholds
parameters
“Display parameters” on page 114
Fault Finder function is automatically triggered in
order to identify the faulty events.
No
: the Fault finder function is not activated (no
fault finding occurs, even if one value exceeds
the thresholds).
NOTE
This parameter is not available when only the Fault Finder function is
available in the module.
If «Fault Finder» parameter is set to Yes, the «OTDR» parameter
is automatically set to No, and vice-versa.
MTS2100 4100 Module US rev08.book Page 113 Jeudi, 1. août 2013 1:43 13