Chapter 6
FTTA-SLM Software option
Saving the trace(s) and generating a report
User Manual
770000102/08
89
In the
Direction
parameter, select/modify the direction, to define
if the measurement has been performed from Origin to Extremity
(
A -> B
) or from Extremity to Origin (
B -> A
)
In the
Location A
and
Location B
parameters, enter/modify the
name of Origin and Extremity.
3
Once all the parameters are configured, press
Save All
menu key.
4
Enter a name for the file in the edition keypad.
or
Click on
Auto Filenaming
menu key to apply the file name defined
in the Setup screen, in
Filenaming
parameter (see
5
Press
Enter
to validate
The icon
displays during saving process.
Once saving is completed, a sound is emitted onto the Platform.
Opening a
report
1
To open the report, press
F
ILE
hardkey
2
In the
Explorer
page, in the directory selected, select the file/report.
The file name is:
For the txt file:
trace file_sor.txt
For the pdf file:
trace file.sor.pdf
3
Press
Load
.
The file opens on the T-BERD/MTS.
NOTE
The sor file and the txt or pdf file will have the same name.
NOTE
The file and the report are saved in the last storage media and direc-
tory selected.
MTS2100 4100 Module US rev08.book Page 89 Jeudi, 1. août 2013 1:43 13