Chapter 6
FTTA-SLM Software option
Configuring the Reflectometry test for FTTA network
82
User Manual
770000102/08
The name of the file is displayed in grey under
Filenaming
parameter
File Content
In this parameter, select the file content for traces saving:
One Trace
in case of traces in overlay, each trace is saved
in a distinct file (.sor extension).
All Traces
in case of traces in overlay, all traces are saved
in one single file (.msor extension)Define the
Auto Store parameter
Save Mode
When a trace or more is displayed, in the parameter
Save Mode
, you can
select three types of methods for storing traces:
File Only
only the trace(s) is/are stored in one/several
file(s), with its extension (.sor or .msor)
File + txt
the trace(s) is/are stored in one/several file(s),
with its extension and one txt file is also
generated.
File + pdf
the trace(s) is/are stored in one/several file(s),
with its extension and one pdf file is also
generated.
Auto store
Select
Yes
to store automatically the trace or traces resulting from each
acquisition according to the filenaming rules.
Operator
Use the arrow
to enter the name of the operator carrying out the
measurement.
Comment
Use the arrow
to enter a comment, which will be displayed in the file
signature, on the upper part of the screen.
Fig. 48
Filenaming - Edition keypad
Predefined
parameters for
naming files
MTS2100 4100 Module US rev08.book Page 82 Jeudi, 1. août 2013 1:43 13