17. Working with sequences
Only one sequence can be active at a time.
The sequence keys are numbered from 1 to 8. The left column of keys 1 – 4 has two incorporated LEDs
per key, the right column of keys 5 - 8 has one incorporated LED per key. The red LEDs display the
status of the sequence, the green LEDs indicate the selected bank.
Red LED is lit:
The sequence is active.
Red LED is not lit:
The sequence is deactivated.
Green LED is lit:
The bank is active.
Green LED is flashing: The bank is preselected, but a sequence has not yet been activated.
17.1 Switching sequence banks
Press and hold the Shift key. Simultaneously press the desired bank key in
the Sequences block (key with two LEDs). The green LED of the selected
bank begins flashing. Now press the desired sequence key. As soon as a
sequence is selected, both the red LED of the sequence key and the green
LED of the bank key are lit.
17.2 The Sequence Control section
Each activated sequence will run according to the programmed runtimes and mode
of flow control. However, it is possible to overwrite these times with the keys and
faders of the Sequence Control section. The Sequence Control section has higher
priority than the previously programmed data.