15.6 Entering the mode of flow control
With the following parameters, you can determine the flow control of a sequence. The parameters are
activated by pressing the desired key on the display in combination with the corresponding key of the
Sequence Control section:
AUTO:
The steps run automatically according to preprogrammed time intervals. The
auto-function is activated by pressing the Rate key in the Sequence Control
section.
MFAD:
The step is faded with the ManFader fader.
GO:
The step is switched with the Go+ and Go- keys.
SOUND:
The step is switched with the Sound function.
15.7 The ID function
The function ID is used to assign sub-numbers to steps you have inserted in a sequence.
Insert (duplicate) a step into the sequence and press the softkey ID to enter the sub-numbers with the
right encoder wheel. You can assign numbers between x.1 to x.9. The actual number of steps is shown
on the left side of the display below the storage matrix, whereas a little further to the right the sub-
numbers are displayed.
15.8 The GO-TO function
With the GO-TO you will have direct access to a step. This function is used above all to leave out some
steps when a sequence is run.
If, for example, the first step of your sequence is active and you wish to activate the eighth step as next
step, press the softkey GO-TO and then enter the number of the desired step either by turning the left
encoder wheel or with the keys of the CUES/CHASE/SEQUENCE section.
Press the softkey EXE-GO to confirm the process.
Important: While you are selecting a step with the GO-TO function, a programmed and activated
sequence is running according to the entered runtimes and mode of flow control.
15.9 The DUP ST function
Use the function DUP ST to duplicate the currently active step.
Select the desired step with the middle encoder wheel and press the softkey DUP ST.
15.10 The DEL ST function
Use the function DEL ST to delete the currently active step.
Select the desired step with the middle encoder wheel and press the softkey DEL ST.
15.11 The CLEAR function
Press the softkey CLEAR to delete the entire sequence.
ATTENTION: There is no additional confirmation prompt!