JB-lighting Lichtanlagen GmbH Sallersteigweg 15 D-89134 Blaustein Telefon ++49(0)7304 9617-0
- 25 -
2.11.4 PARNUM / Numbering the PAR section
With the PARNUM function, you can number the PAR channels on the three PAR pages available on the
display either per page from 1 – 32 or consecutively from 1 – 96.
Consecutive numbering:
PARNUM not displayed inverted:
PAR NUMBERING : CONTINUOUS
Display of the PAR channels:
Numbering per page:
PARNUM displayed inverted:
PAR NUMBERING : SINGLE PAGE
2.11.5 PARMUL / Accessing PAR fader banks
The PARMUL function controls the access to the fader banks, which can be switched four times.
PARMUL not displayed inverted:
PAR FADER MODE : SINGLE BANK
If on a bank the value of faders is greater than zero, the faders will be switched to another bank not until
the operator slides the fader back down to zero, i.e. the corresponding fader can never be used by more
than one bank at a time.
PARMUL displayed inverted:
PAR FADER MODE : MULTI BANK
If on a bank the value of faders is greater than zero, the faders will remain active when the operator
switches to another bank. By undershooting the corresponding fader value, the faders can be activated
on the bank switched to, and thus be used four times.