3.8.2 Connection of
PureLink
Chlorine Generator Electronics to an AquaLink
®
Control
System
The chlorine generator electronics in the PureLink Power Center and the AquaLink
controller require a
four (4) wire connection to communicate. Any outdoor rated four (4) conductor cable, minimum 22 AWG,
can be used. Locate the appropriate screw terminals on the circuit board according to Figures 16. Wire the
chlorine generator Power Interface Board (PIB)
from the red 4-pin terminal bar to the AquaLink
red 4-pin
terminal bar (see Figure 16).
Referring to Figures 2a or 2b, wire the PureLink power center transformer to the load side of the filter pump
relay.
Figure 16. Wiring a PureLink
Control System Network
PureLink
Power Center
Chlorine Generator
Power Interface Board
4 3 2 1
RED
BLK
YEL
GRN
Red, 4-Pin
Terminal Bar
Page 24
ENGLISH
Page 24
ENGLISH
Jandy
®
AquaPure
®
/PureLink™ Power Center and Cell Kit
|
Installation and Operation Manual