7.2 Service Codes
Code Number Possible Cause
Corrective Action
120
Low current in forward direction to Cell.
1. Clean cell if necessary (see
Section 6.3
).
2. Check DC Cord.
121
Low current in reverse direction to Cell.
1. Clean cell if necessary (see
Section 6.3
).
2. Check DC Cord.
123
Extremely Low current to Cell.
1. Clean or replace cell if necessary (see
Section 6.3
).
2. Check DC Cord.
124
Higher than normal Current to Cell.
Contact a pool professional.
125
Cell needs to be cleaned.
Clean cell if necessary (see
Section 6.3
).
126
Low current in forward direction and VAC input
voltage below 100/200 VAC.
Contact a pool professional.
127
Low current in reverse direction and VAC input
voltage below 100/200 VAC.
Contact a pool professional.
144
Low Salinity (below 2.0 gpl).
Add salt to pool to achieve 3.0 gpl (see
Section 4.7
).
145
High Salinity (above 4.0 gpl).
Backwash filter if a DE filter is installed. Partially
drain pool and dilute with fresh water until salinity
returns to 3.0 to 3.5 gpl.
170
Possible Front board service condition or unit not
correctly wired to 120 VAC.
Contact a pool professional.
171
Possible Backboard service condition.
Contact a pool professional.
172
Flow Sensor service condition or flow sensor is
unplugged.
Contact a pool professional.
173
Low VAC input voltage and on board power supply is
not regulated or unit not correctly wired.
Unit wired to improper AC voltage. Contact a pool
professional.
174
Pool Temperature is too high for operation of
AquaPure.
Flow/Salinity Sensor indicates water temperature
at sensor above 108ºF (42°C). Reduce water
temperature.
175
Flow Sensor air lock condition or very low salinity.
Verify proper flow/temp/salinity sensor installation
(see
Section 3, Figure 11
). Check salinity with Myron
“L” meter calibrated for NaCl or test strips. Add salt
as necessary (see
Sections 4.5 through 4.7
).
7.3 Level 2 Service Codes
If you encounter a Level 2 Service Code, contact your local pool professional for service.
Code Number Possible Cause
Corrective Action
180
Heated sensor element not heating.
(Generates 172 code)
Contact a pool professional.
181
Flow sensor temperature sensor failure.
(Generates 172 code - flow sensor service) )
Contact a pool professional.
182
Salinity Sensor sees less than 0.2 gpl of salt, no salt
in pool or sensor air locked.
(Generates 175 code – flow sensor air lock)
Contact a pool professional.
183-186
Flow salinity sensor temperature probe error codes.
(They will all generate 172 codes which indicate flow
sensor service is required)
Contact a pool professional.