Power Center Wiring Diagram
CHLORINE GENERATOR
POWER INTERFACE
J13
J12
J11
BLK/YEL
BLK/RED
BLK/WHT
BLACK
Factory wired for 240 VAC service; Middle primary
wires connected together. If electrical service is
120VAC, the power supply must be modified.
Flow, Salinity, Temp Sensors
RIBBON CABLE TO
USER INTERFACE
GR
Y
BK R
LOW VOLTAGE RACEWAY
HIGH VOLTAGE
HEAT SINK
L - BRACKET
CHLORINE GENERATOR
USER INTERFACE
To Chlorine Generator Cell
View of chlorine generator PCB
shown with transformers and
components located behind front
face plate.
PRIMARY
SECONDARY
CHLORINE GENERATOR
TRANSFORMER
BLK/WHT
BLK/YEL
BLK/RED
BLK
Use Copper Conductors Only – Rated for 90°C Minimum
Re-wired for
120 VAC
Load 2
Load 1
Load 1 (Hot)
Ground (Chassis)
Ground (Chassis)
To Earth
Bonding Point
To Earth
Bonding Point
Load 2 (Neutral)
240
VAC
Pool Pump Timer
Circuit Breaker
Panel
Line 1
Line 2
Ground
50/60 Hz
3 wire
3
12
6
9
Filter Pump
(240 VAC)
Figure 2c. Wiring Diagram for the AquaPure
®
System
The power pack must be interlocked/interconnected with the pool pump motor power source to ensure
that the chlorinator only operates when the pool pump is operating. The flow sensor feature of the
chlorinator cell is intended to be used as a backup only and should not be used as the sole source of flow
detection.
WARNING
Page 11
ENGLISH
Page 11
ENGLISH
Jandy
®
AquaPure
®
/PureLink™ Power Center and Cell Kit
|
Installation and Operation Manual