A
Sensor
Sensor
Sensor
Flow
UP
Flow
Flow
A
C
B
(
)
UP
UP
Figure 3.
Chlorine Generator Cell and Sensor Orientation with Flow Direction
3.2.2 Recommended Plumbing Configuration
The preferred installation is that the cell and sensor are plumbed in the common line after (downstream)
the heater. The sensor is designed to be plumbed into the 3-port cell. Figure 4 illustrates the recommended
plumbing configuration, which results in the most reliable operation.
NOTE
The AquaPure® and PureLink
TM
systems are powered from the LOAD SIDE of the pool circulation pump
relay. This ensures that the cell only operates when the pool pump is energized. The flow sensor serves as a
secondary means to ensure there is sufficient flow for the cell to operate.
Spa
Bypass for
Spillover
Pool
Return
Cell
Spa
Return
JANDY
Sensor
Control/Power
Center
Heater
Figure 4.
Recommended Plumbing Configuration for Pool/Spa Combination Systems
Page 13
ENGLISH
Page 13
ENGLISH
Jandy
®
AquaPure
®
/PureLink™ Power Center and Cell Kit
|
Installation and Operation Manual