Operating User Interface Controls when
AquaLink
®
RS Control System is Online
Chlorine
Production Rate
Adjustment
with
AquaLink RS
Online
The user interface can be used to adjust the output production rate (%) when the salt
water chlorinator system is controlled by the AquaLink RS only when the AquaLink
RS is placed into service mode. When the down arrow button
A
or the up arrow
button
B
is pressed, a
JA
in the display indicates that the AquaLink RS is controlling
the entire system, including the output production rates.
The AquaLink RS Control System must be set to Service Mode before you can
change the chlorine production rate from the control/power center user interface
NOTE
The Boost button at the user interface will start Boost cycle whether the AquaLink
RS is online or offline.
AquaLink
RS
Control System
Press
the Mode Select button to move the AquaLink RS from Auto Mode into
Service Mode. The Service indicator light will turn ON.
Press
the Valve Select button to choose either Pool Mode to change pool chlorine
production, or Spa Mode to change spa chlorine production.
Press
the Filter Pump button to turn on the pump and apply power to the sanitizing
system.
Control/Power
Center User
Interface
Press
the down arrow button
A
or the up arrow button
B
to change the chlorine
production rate in 5% increments. Generally, adjustments to production should be
made in 10% increments.
AquaLink RS
Control System
Press
the Mode Select button to put the AquaLink RS in the Time Out mode.
Press
the Mode Select button again to place it back into Auto mode.
NOTE
The AquaLink RS control system must be in pool mode to change the pool chlorine production rate setting;
and it must be in spa mode to change the spa chlorine production rate setting. Use the valve select button
to switch between the two modes. The system must be cycled through SERVICE, TIME OUT, then back to
AUTO to accept the Pool Setting versus the Spa Setting.
5.2 Reading the Display
CELL ON
The
CELL ON
indicator shows that the cell has been turned on. Some reasons
for the
CELL ON
indicator not being on during normal operation, are:
CHLORINE
PRODUCTION RATE
set to 00%,
CHLORINE PRODUCTION RATE
set to less than
100% and
CELL RESTING
appears during cell rest period,
NO FLOW
condition,
two minutes before automatic cleaning cycle, low temperature cut off has been
activated, or a service related problem such as a salinity level below 2.0 gpl or
salinity level too high.
CELL RESTING
During
the normal chlorine production cycle when the unit is set for less than
100%, the cell will periodically rest; that is, the unit will not make chlorine. The
CELL RESTING
indicator shows that the cell has been turned off by the control
power center.
FLOW or NO FLOW
Indication
When
the control/power center determines that water is flowing past the flow/temp/
salinity sensor, the
FLOW
indicator is displayed. When no flow is detected,
NO
FLOW
is displayed on the LCD and the cell is turned off.
Page 32
ENGLISH
Page 32
ENGLISH
Jandy
®
AquaPure
®
/PureLink™ Power Center and Cell Kit
|
Installation and Operation Manual